Watts SmartStream UV WA002 Installation, Operation And Maintenance Manual

Watts SmartStream UV WA002 Installation, Operation And Maintenance Manual

254 nanometer germicidal uv disinfection systems chemical free disinfection of water

Advertisement

Installation, Operation and
Maintenance Manual
254 Nanometer Germicidal
UV Disinfection Systems
Models
WA002 WA006 WA008 WA012
SmartStream
Chemical Free Disinfection of Water
WARNING
!
Read this Manual BEFORE using this
equipment. Failure to read and follow
all safety and user information can
result in death, serious personal injury,
property damage, or damage to the equipment.
Keep this Manual for future reference.
NOTICE
This system should only be installed and main-
tained by a qualified professional. The system
MUST be installed in accordance with all appli-
cable national, state and local codes.
Introduction
The Watts SmartStream
line of ultraviolet disinfection systems
provide protection against microbiological contamination in water for
residential and commercial applications.
Disinfection of water with SmartStream
process. When contaminated water is exposed to SmartStream's
254 nanometer UV light, the UV light penetrates the cell walls of mi-
croorganisms and disrupts their genetic deoxyribonucleic acid (DNA)
material. This quickly inactivates microorganisms by destroying their
ability to replicate and infect.
WARNING
!
DO NOT rely solely on this system to make
water safe to drink. SmartStream
tion systems are intended to be used as part of
a well designed water treatment system. Water
that contains microbiological contamination
should be tested regularly to ensure its quality
and safety at the point of use.
WARNING
!
DO NOT look directly at the UV lamp while it is
ON. Permanent serious eye injury could occur.
UV
is a simple, rapid physical
UV disinfec-
SmartStream UV is certified by the Water Quality
Association (WQA) to NSF/ANSI Standard 372
for lead free.

Table of Contents

Installation Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
System Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Product Specification Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Feed Water Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Lamp and Quartz Sleeve Replacement . . . . . . . . . . . . . . . . . . . . . . . 8
Disinfection Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Warranty and Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
IOM-WQ-SmartStream-A

Advertisement

Table of Contents
loading

Summary of Contents for Watts SmartStream UV WA002

  • Page 1: Table Of Contents

    The system MUST be installed in accordance with all appli- cable national, state and local codes. Introduction The Watts SmartStream line of ultraviolet disinfection systems ™ provide protection against microbiological contamination in water for SmartStream UV is certified by the Water Quality ™...
  • Page 2: Installation Precautions

    • DO NOT install the system backwards with the use only parts recommended and supplied feed water line connected to the outlet. by Watts. DO NOT add components to or • DO NOT install where system is exposed to remove components from this system.
  • Page 3: System Specifications

    SmartStream UV System Part Number Identification Key ™ Prefix "W" "Controller Series" "GPM" "Connection Type" "Pipe Size" "Plug" "Accessories" Watts Controller Type GPM of System Connection Port Pipe Size A: North American Accessories A: Controller A (3-Digits) Types: B: 3/8"...
  • Page 4: Product Specification Tables

    3/4" NPT-M 3/4" NPT-M 1" NPT-M CHAMBER MATERIAL 304 SS INPUT VOLTAGE 120 VAC 60 Hz or 230 VAC 50 Hz SYSTEM MAX INPUT POWER (Watts) 18.6 LAMP MAX ELECTRICAL POWER (Watts) VISUAL ALARM Green/Red LED AUDIBLE ALARM AUDIBLE ALARM MUTE MIN/MAX AMBIENT AIR TEMPERATURE / 32°F (0°C) to 122°F (50°C) / 90% RH (non-condensing)
  • Page 5: Feed Water Requirements

    Feed Water Requirements Installation WARNING Please review operating pressures, temperatures and water chemistry limitations to ensure compatibility. Inspect wall for hidden wiring before drilling any holes or installing screws. Max Water Pressure 100 psi (6.9 bar) 1. Remove all system components from packaging and 6.5-8.5 inspect for any damage.
  • Page 6: Installation Diagram

    Typical Installation Diagram...
  • Page 7: Maintenance

    Parts List ITEM QTY. ORDERING CODE DESCRIPTION UV CHAMBER 2.5" OD 2 GPM 3/8" MNPT FOR A SERIES UV CHAMBER 2.5" OD 6 GPM 3/4" MNPT FOR A SERIES UV CHAMBER 2.5" OD 8 GPM 3/4" MNPT FOR A SERIES UV CHAMBER 2.5"...
  • Page 8: Lamp And Quartz Sleeve Replacement

    Lamp and Quartz Sleeve Replacement Procedure 7. Remove the quartz sleeve from the reactor chamber. WARNING 8. Fully insert a new quartz sleeve into the reactor chamber. Be If any water comes in contact with any electri- careful not to force the quartz sleeve, breakage may occur. cal components, dry the components immedi- Then install the o-ring over the quartz sleeve.
  • Page 9: Disinfection Procedure

    Disinfection Procedure 4. Reinstall the filter housing and open up the prefilter isolation NOTICE valves. DO NOT unplug the system. 5. Flush 2 reactor chamber volumes of water through the UV system then stop and let the solution remain in the UV sys- 1.
  • Page 10: Warranty And Conditions

    INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT. USA: Tel: (800) 659-8400 • Fax: (800) 659-8402 • Watts.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • Watts.ca Latin America: Tel: (52) 81-1001-8600 •...