Watts Premier ZEROWASTE ZRO-4 Installation, Operation And Maintenance Manual

Watts Premier ZEROWASTE ZRO-4 Installation, Operation And Maintenance Manual

Reverse osmosis system
Hide thumbs Also See for Premier ZEROWASTE ZRO-4:

Advertisement

Quick Links

INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Please read carefully before proceeding with installation. Failure to follow attached
instructions or operating parameters may lead to the product's failure.
******************************************************************************************
ZEROWASTE
Premier, Inc.
Phone: 800-752-5582
Warning
Save manual for future reference.
Model ZRO-4
REVERSE OSMOSIS SYSTEM
®
System is in compliance with the Uniform Plumbing
Code (UPC®),International Plumbing Code (IPC®),
and IGC 159-2000A
8716 W Ludlow Drive Suite #1
www.PremierH2o.com
®
Peoria, AZ 85381
Fax: 623-866-5666

Advertisement

Table of Contents
loading

Summary of Contents for Watts Premier ZEROWASTE ZRO-4

  • Page 1 ® INSTALLATION, OPERATION AND MAINTENANCE MANUAL Warning Please read carefully before proceeding with installation. Failure to follow attached instructions or operating parameters may lead to the product’s failure. ****************************************************************************************** Save manual for future reference. Model ZRO-4 ZEROWASTE REVERSE OSMOSIS SYSTEM ®...
  • Page 2 Thank you for your purchase of a state of the art Premier ZeroWaste Reverse Osmosis (RO) water treatment system. ® Water quality concerns are quickly becoming more of a focus for the public. Lately you may have heard about contaminants in the drinking water, such as arsenic, perchlorate, and chromium.
  • Page 3: Table Of Contents

    ** Before installation, please take a moment to fill out the warranty card on page 21-22. Thank you for your purchase of a Premier ZeroWaste Reverse Osmosis system. With proper installation ® and maintenance, this system will provide you with high quality water for years to come. All of Premier water enhancement products are rigorously tested by independent laboratories for safety and reliability.
  • Page 4: Operational Parameters

    Operational Parameters Installation must comply with State and local plumbing regulations. This system is to be installed to treat cold water only. Operating Temperatures: Maximum 100°F (37.8°C) Minimum 40°F (4.4°C) Operating Pressure: Maximum 85 psi (6.0 kg/cm Minimum 40 psi (2.80 kg/cm pH Parameters: Maximum 11 Minimum 2...
  • Page 5: Important Notice

    ***IMPORTANT NOTICE*** Not recommended for use on homes equipped with tankless water heaters. Contact Premier for specific details regarding this unit and tankless water heaters. System was tested in a laboratory setting utilizing a hot water heater of 40 gallons set at 120º F. Performance may vary if your heater is smaller than 40 gallons or set above 120º...
  • Page 6: Installation Of Faucet

    Installation of Faucet Step 6 Place the escutcheon chrome plate and the black rubber washer on the faucet shank. (Parts found in faucet parts bag). Step 7 Insert the faucet shank through the hole in sink and let it rest on the sink top. Step 8 From the underside of the sink, slide on the locating washer, lock washer and brass nut onto the shank.
  • Page 7: Adapt-A-Valve Installation

    Adapt-a-Valve Installation Water supply line to the system must be from the cold water supply line only. Hot water connection is used for rinse water return and must be connected for system to function correctly. * Washer Configuration for 3/8” Configuration for 1/2”...
  • Page 8: Blue Tube Connection (From The Ro Module To Tank)

    Blue Tube Connection (From The RO Module To TANK) Position tank in desired location. Stand it upright or lay it on Step 17 its side (using the black plastic stand). Measure the blue tube (marked “TANK”) from the RO module to the tank and cut it to length leaving a straight, square edge.
  • Page 9: Month System Maintenance

    6 Month System Maintenance - Filter Kit #560038 *Order filters by calling 1-800-752-5582 or buy online at www.PremierH2o.com. Items needed: √ Stage 1 - Sediment Filter (part #: 104017) √ Stage 2 - Carbon Block Filter (part #: 101009-White End Caps) Note: The filter wrench pictured (Part # 164003) may be purchased from Premier to aid with twist- ing off filter housings but is not required.
  • Page 10: Annual Maintenance

    Annual Maintenance - Filter Kit #560032 √ Stage 1 - Sediment Filter (PN# 104017) √ Stage 4 - 10” Final Polishing Inline filter √ Stage 2 - Carbon Block Filter (PN# 101009) (PN 560010) √ 1/4 Cup of common household bleach. NOTICE: Sanitizing of unit is recommended - RO storage tank must be drained.
  • Page 11: Membrane Maintenance

    TIP: This is a good time to check the air pressure in your storage tank. For instruc- tions please see page 17. Step 14: Follow Steps 8 through 10 in the Six Month System Maintenance (Page 14) for startup directions. This reverse osmosis system contains a replaceable component (the RO membrane) which is criti- cal to the efficiency of the system.
  • Page 12: Check Air Pressure In The Tank

    Check Air Pressure in the Tank Check air pressure only when tank is empty of water! Important: Check air pressure in the storage tank when you notice a decrease in available water from the RO system. Air can be added with a bicycle pump using the schrader valve that is located on the lower side of the tank behind a blue plastic cap.
  • Page 13: Faucet Adjustment

    Adjust Faucet If the faucet has developed a drip it can be corrected by following the steps outlined below. Step 1 Remove faucet Spout first. Position both thumbs on the back edge of the lever and push forward. Step 2 Lever will slide forward and completely off of the faucet base.
  • Page 14: Performance Data Sheet

    Performance Data Sheet ZRO-4 ZeroWaste ® Watts Premier 8716 W Ludlow Drive Suite #1 Peoria, AZ 85381 480) 675-7995 GENERAL USE CONDITIONS: 1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. Do not use with water that is microbiologically unsafe or unknown quality without adequate disinfection before and after the system.
  • Page 15: Arsenic Fact Sheet

    Arsenic Fact Sheet Arsenic (As) is a naturally occurring contaminant found in many ground waters. Arsenic in water has no color, taste or odor. It must be measured by an arsenic test kit or lab test. Public water utilities must have their water tested for arsenic. You can obtain the results from your water utility contained with in your consumer confidence report.
  • Page 17: Parts List

    Item # Part # Description Item # Part # Description 137013 BRACKET-4SV-STEEL WHITE 116023 FAUCET-AG-CHROME 146001 SCREW- #10-3/4” PHIL PAN HEAD 134018 VALVE-BALL-PLAS-ELB 146004 SCREW- #10-1” PHIL PAN HEAD 119007 TANK PRESS 3 GAL WHITE 164006 CLIP-MTG-MEM-VESSEL 119028 TANK STAND 337002 BRACKET 16 GAUGE CRS 125017 CON-PL-1/4C X 1/4M 113007 LID-WHITE 1/4”...
  • Page 18: Other Products By Premier

    SERVICE RECORD DATE OF PURCHASE DATE OF INSTALL INSTALLED BY SERIAL NO. NAME: Date of (6 mos.) (6 mos.) (1 yr.) (2-5 yrs.) OTHER Maintenance 1st stage 2nd stage Final Filter TFM Memb. Sediment Carbon Block Carbon NOTES:...
  • Page 19: Warranty

    Reverse Osmosis System is defective in workmanship (excluding replaceable filters and membranes), return unit ® after obtaining a return authorization (see below), less tank, within 1 year of original retail purchase, Watts Premier will repair or, at Watts Premier’s option, replace the system at no charge.

Table of Contents