Advertisement

Quick Links

INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Please read carefully before proceeding with installation. Your failure to follow any attached instructions
Refer to enclosed warranty for operating parameters to ensure proper use with your water supply.
Watts Premier, Inc.
Phone: 800-752-5582
P/N 299086
or operating parameters may lead to the product's failure.
Save manual for future reference
Model: ZRO-PURE
8716 W Ludlow Drive Suite #1
www.wattspremier.com
Warning
Page 1
Peoria, AZ 85381
Fax: 623-866-5666
Manual Edition: 01/19/2012

Advertisement

Table of Contents
loading

Summary of Contents for Watts ZRO-PURE

  • Page 1 Please read carefully before proceeding with installation. Your failure to follow any attached instructions or operating parameters may lead to the product’s failure. Save manual for future reference Model: ZRO-PURE Refer to enclosed warranty for operating parameters to ensure proper use with your water supply. Watts Premier, Inc.
  • Page 2 Thank you for your purchase of a state of the art Watts Premier Reverse Osmosis (RO) water treatment system. Water quality concerns are becoming more of a focus for the public. You may have heard about contaminants in the drinking water such as Arsenic, Perchlorate, Chromium, Cryptosporidium or Giardia.
  • Page 3: Table Of Contents

    Product Technical & Warranty Information Performance Data Sheet ........................ 16 Arsenic Fact Sheet ......................... 17 Nitrate / Nitrite Test Instructions ...................... 18 Other Products from Watts Premier ..................19-20 Warranty Registration ........................ 21-22 Service Record ..........................23 Limited Warranty ..........................24...
  • Page 4: Operational Parameters

    Operational Parameters Installation must comply with State and local plumbing regulations. Do not use with water that is micro biologically unsafe or of unknown quality without adequate disinfection before or after the system. System is intended to be installed using the cold water supply only. Operating Temperatures: Maximum 100°F (37.8°C) Minimum 40°F (4.4°C)
  • Page 5: Plumbing Diagram And Parts List

    1/4" GREEN TUBE ***IMPORTANT NOTICE*** Not recommended for use on homes equipped with tankless water heaters. Contact Watts Premier for specific details regarding this unit and tankless water heaters. System was tested in a laboratory setting utilizing a hot water heater of 40 gallons set at 120º F.
  • Page 6: Drill A Hole For The Reverse Osmosis Faucet

    (If you are already using it for a sprayer or soap dispenser, see step 1) Porcelain sinks are extremely hard and can crack or chip easily. Use extreme caution when drilling. Watts accepts no responsibility for damage resulting from the installation of faucet. Diamond tip bit recommended.
  • Page 7: Faucet Installation

    Ferrule (Sleeve) to be replaced sooner. For replacement, Compression Nut look for battery number CR2032 (Watts p/n:116080) which should be available at your local battery store or contact Premier at 800-752-5582. You may also order online at www.wattspremier.com.
  • Page 8: Adapt-A-Valve Installation

    Adapt-a-Valve Installation Water supply line to the system must be from the cold water supply line only. Hot water connection is used for rinse water return and must be connected for system to function correctly. Verify contents prior to installation: Black Collet ( 2 ) - Plastic Adapt-a-Valve with black collet...
  • Page 9: Green Tube Connection (From Adapt-A-Valve To Pump)

    In the parts bag locate two 3/8” male stem adapters and insert them into the upper ports on the ESOV as pictured in the photos below. Green Tube Connection (From Adapt-a-Valve to Pump) Insert the open end 1/4” green tube from the Adapt-a-Valve into Step 14 the 1/4”...
  • Page 10: Tank Ball Valve Installation

    Tank Ball Valve Installation Teflon tape must be applied in a clockwise direction. Wrap Step 18 (7 to 12 turns) around the male pipe threads (MPT) on the stainless steel fitting on top of the tank. Thread the quick connect ball valve (supplied in the parts bag) Step 19 onto the stainless steel connector on the tank.
  • Page 11: Start Up Instructions

    Congratulations! You have completed the installation of your new Reverse Osmosis system. Please Follow the Startup Instructions. Start up Instructions Warning: To prevent the possibility of electrical shock, clean up any water on cabinet floor and dry all water from outside of RO unit. Turn on the incoming hot and cold water angle stop valves.
  • Page 12: Changing The Filter Cartridges

    Changing The Filter Cartridges Your RO module is equipped with valved heads which will automatically turn off the water supply to each filter when the filter is released, thus you do not need to turn off the incoming water supply at the Adapt-a-Valve.
  • Page 13: Annual Sanitization

    Annual Sanitization Sanitization procedure must be performed before a filter change. Note: Step 1 Turn off the water supply to your RO system, unplug transformer and open the RO faucet to drain the storage tank. Step 2 Disconnect the blue tube from the ball valve on the storage tank (see page 6 for quick connect fitting use instructions).
  • Page 14: Check Air Pressure In The Tank

    Check Air Pressure in the Tank Check air pressure only when tank is empty of water! Important: Check air pressure in the storage tank when you notice a decrease in available water from the RO system. Air can be added with a bicycle pump using the schrader valve that is located on the lower side of the tank behind a blue plastic cap.
  • Page 15: Troubleshooting

    TROUBLE SHOOTING Problem Cause Solution 1. Low/Slow Production Low Water Pressure Make sure water supply is turned on and Adapta Valve is all the way open. Crimps in tubing Check tubing and straighten or replace as necessary. Clogged pre-filters Replace pre-filters. Fouled membrane Replace membrane.
  • Page 16: Product Technical & Warranty Information Performance Data Sheet

    TECHNICAL & WARRANTY INFORMATION Watts Premier Inc. 8716 W Ludlow Drive Suite #1 Peoria, AZ 85381 ZRO-Pure System conforms to Standard 58 for specific claims GENERAL USE CONDITIONS: 1. System to be used with municipal or well water sources treated and tested on regular basis to insure bacteriological safe quality. DO NOT use with water that is microbiologically unsafe or unknown quality without adequate disinfection before and after the system.
  • Page 17: Arsenic Fact Sheet

    Arsenic Fact Sheet Arsenic (As) is a naturally occurring contaminant found in many ground waters. Arsenic in water has no color, taste or odor. It must be measured by an arsenic test kit or lab test. Public water utilities must have their water tested for arsenic. You can obtain the results from your water utility contained with in your consumer confidence report.
  • Page 18: Nitrate / Nitrite Test Instructions

    Nitrate / Nitrite Test Instruction Page 18...
  • Page 19: Other Products From Watts Premier

    15,000 gallons per year! Part No. 500800 *$229.99 each ZRO-PURE Six Month Filter Kit Compatible with the Premier ZRO-PURE Reverse Osmosis filtration system. This kit includes one sediment filter and one 5 micron carbon pre filter. Part No. 531102 *$24.95/ea Pocket Total Dissolved Solids (TDS) Monitor Test water electronically to verify reverse osmosis membrane effectiveness.
  • Page 20 Removing chlorine from your shower Special Chlorgon & KDF media – More effective then carbon medias with hot water applications in the removal of the following. √ Free Chlorine (CL-) √ Iron oxide (rust water) √ Combined Chlorine (Sodium Hypochlorite) √...
  • Page 21: Warranty Registration

    FREE Fax this form directly to us. 4. Mail in the information. Filter Reminder Please complete the form below. Mail to: Watts Premier 8716 W Ludlow Dr. Suite #1 Notice Peoria, AZ 85381 Premier Inc. is concerned for the safety of your personal information. Premier collects personal information when you register with Premier. This information is stored in our data base and we do not rent, sell, or share personal information with other people or nonaffiliated companies.
  • Page 22 Iowa Department of Public Health - Sales in Iowa require this to be completed, signed and returned. These signatures will be retained on file for two years. Insert into envelope and return to Premier Watts Premier 8716 W Ludlow Drive Suite #1 Peoria, AZ 85381...
  • Page 23: Service Record

    Service Record Model Number:__________ Serial Number:___________ Date of Purchase:__________ Date of Install:___________ Installed by:_____________ Sediment Carbon Membrane Carbon Date Filter Pre-Filter Post-Filter (6 months) (6 months) (2-5 years) (12months) NOTES: Page 23...
  • Page 24: Limited Warranty

    Limited Warranty What your Warranty Covers: If any part of your Premier Reverse Osmosis System is defective in workmanship (excluding replaceable filters and membranes), return unit after obtaining a return authorization (see below), less tank, within 1 year of original retail purchase, Premier will repair or, at Premier’s option, replace the system at no charge.