Appendix A: Reporting Codes - DSC Power632 Installation Manual

Hide thumbs Also See for Power632:
Table of Contents

Advertisement

Appendix A: Reporting Codes

The following tables contain Contact ID and Automatic SIA for-
mat reporting codes. For more information on reporting code
formats and notes about individual reporting codes, see sec-
tions 5.8 "Communicator – Reporting Codes" and 5.9 "Com-
municator – Reporting Formats" .
Contact ID
The first digit (in parentheses) will automatically be sent by the
control panel. The second two digits are programmed to indi-
cate specific information about the signal.
For example, if zone 1 is an entry/exit point, you could program
the event code as [34]. The central station would receive the
following:
*BURG - ENTRY/EXIT - 1
where the "1" indicates which zone went into alarm.
Section #
Reporting Code
[320]
Zone Alarms
[324]
Zone Restorals
[330]
Zone Tamper/Restoral
[334]
[328]
Duress Alarm
[328]
Opening After Alarm
[328]
Recent Closing
[328]
Zone Expander Supervi-
sory Alarm/Rest.
[328]
Cross Zone (Police Code)
Alarm
[329]
[F] Key Alarm/Rest.
[329]
[A] Key Alarm/Rest.
[329]
[P] Key Alarm/Rest.
[329]
PGM2 Alarm/Rest.
[338]
General System Tamper/
Rest.
[338]
Keypad Lockout
[339-343]
Closings
[343]
Partial Closing
[343]
Special Closing
[344-348]
Openings
[348]
Auto-Arm Cancellation
[348]
Special Opening
[349-350]
Battery Trouble/Rest.
* A/R = Alarms/Restorals; T/R = Tampers/Restorals; O/C = Openings/Closings; MA/R = Miscellaneous Alarms/Restorals; T = Test Transmissions
Code Sent When...
zone goes into alarm
alarm condition has been restored
zone exhibits a tamper condition/tamper condition
restored
duress code entered at keypad
system disarmed with alarm in memory
alarm occurs within two minutes of system arming
panel loses/restores supervisory transmission over the
Keybus from enrolled PC5132 module or keypads with
zone inputs
two zones on the same partition go into alarm during
any given armed-to-armed period (incl. 24 hr zones)
Keypad fire alarm (alarm and restoral rep. codes sent
together)
Keypad auxiliary alarm (alarm and restoral rep. codes
sent together)
Keypad panic alarm (alarm and restoral rep. codes sent
together)
a panic button wired to PGM2 is pressed / access code
is entered (PGM2 programmed as option [23] or [24])
a 2-wire smoke detector wired to PGM2 goes into alarm/
alarm is cleared (PGM2 programmed as option [04])
Enrolled module with tamper inputs has a tamper alarm/
all module tampers restored
Maximum number of incorrect access codes has been
entered at a keypad
System armed (user 01-34, 40-42 indicated)
One or more zones bypassed when system armed
Closing (arming) using one of the following methods:
quick arm, auto arm, keyswitch, function key, mainte-
nance code, DLS software
System disarmed (user 01-34, 40-42 indicated)
Auto-arm cancelled
Opening (disarming) using one of the following meth-
ods: keyswitch, maintenance code, DLS software
PC1555MX battery is low/battery restored
SIA Format - Level 2 (Hardcoded)
The SIA communication format used in this product follows the
level 2 specifications of the SIA Digital Communication Stan-
dard - January 1996. This format will send the account code
along with its data transmission. The transmission would look
similar to the following at the receiver:
N Ri01
N
=
Ri01
=
BA
=
01
=
Dialer
Direction*
A/R
A/R
T/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
A/R
T/R
T/R
O/C
O/C
O/C
O/C
O/C
O/C
MA/R
** UU = User Number (user01-42); ZZ = Zone Number (01-32)
BA 01
New Event
Partition /Area Identifier
Burglary Alarm
Zone 1
Automatic
SIA Auto Rep
Contact ID
Codes**
Codes
(1) 3A
See Table 3
(1) 3A
(1) 44
TA-ZZ/TR-ZZ
(1) 21
HA-00
(4) A6
OR-00
(4) 59
CR-00
(1) 43
UA-00/UH-00
(1) 4A
BV-00
(1) 15
FA-00/FH-00
(1) AA
MA-00/MH-00
(1) 2A
PA-00/PH-00
(1) 4A
UA-99/UH-99
(1) 11
FA-99/FH-99
(1) 45
TA-00/TR-00
(4) 21
JA-00
(4) A2
CL-UU
(4) 7A
CG-ZZ
(4) AA
CL-00
(4) A2
OP-UU
(4) A5
CE-00
(4) AA
OP-00
(3) A2
YT-00/YR-00
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents