[08] Restoral Reporting Codes
Zones 9 to 16
These reporting codes are used by the communicator to
transmit a zone restoral for zones 9 to 16. Use instructions in
section [05] as a guide for programming.

[09] Utility Alarm Reporting Codes

These reporting codes are used by the communicator to
transmit the following conditions.
• Fire Zone
• Auxiliary Input Zone
• Battery Trouble
• AC Failure Trouble
• Day Zone(s) Trouble
• Bell Circuit Trouble
• Fire Zone Trouble
• Auxiliary Power Supply Trouble
Use instructions in section [05] as a guide for programming.
See "Terminal Connections" section of manual for a
description of the operation of the Fire Zone and the
Auxiliary Input Zone. Section [28] contains options for
Auxiliary Input Zone. The Battery Trouble reporting code will
be sent when the battery voltage drops below 11.5 volts.
This reporting code will also be sent because of a battery
fuse failure. The battery is tested under load every 10
seconds. Only one transmission will be sent during an arm
or disarm period to prevent multiple transmission from a
weak battery. The AC Failure Trouble reporting code will be
sent after the delay time programmed in section [22]. This
prevents transmissions during temporary power failures.
Auxiliary Power Supply Trouble reporting code is sent when
the auxiliary power supply fuse failed. The Bell Circuit
Trouble reporting code is sent when the bell circuit is open
or the fuse failed. The Fire Zone Trouble code is sent when
the fire zone becomes open circuit (E.O.L. resistor is
disconnected). The Day Zone Trouble code is sent when
any zone defined as a Day Zone (see section [16], [17])
goes open when the system is disarmed. See [Q][2]
"Trouble Command" section for additional description of
troubles.

[10] Utility Restoral Reporting Codes

These reporting codes are used by the communicator to
transmit the following list of restoral conditions which
correspond to alarm conditions in section [09]. Use
instructions in section [05] as a guide for programming.
• Fire Zone
• Auxiliary Input Zone
• Battery Trouble
• AC Trouble
• Day Zone(s) Trouble
• Bell Circuit Trouble
• Fire Zone Trouble
• Auxiliary Power Supply Trouble
[11] Reporting Codes for Closing
(Arming) with Access Codes 1 to 8
The reporting codes in sections [11] to [14] are used to
identify "Openings and Closings" (disarming and arming of
the system) by user access code.
After entering the section code [11], enter 8 two digit
reporting codes. The 8 reporting codes correspond to the
first 8 access codes which are programmed using the
[Q][5] command. When the system is armed using one of
the access codes, the corresponding reporting code is
transmitted.
When transmitting in any of the extended formats, (see
examples in section [05]), closing codes would be
programmed as follows. [C1], [C2], [C3], [C4], [C5], [C6],
[C7], [C8]........
Where the first digit "HEX C" is one which is used to
represent a closing signal (this could be another number
depending on what is used at the monitoring station) the 2nd
digit represents the access code which was used to arm the
system.
The closing code transmission takes place after the exit
delay time. Therefore if the system is armed and disarmed
before the expiry of the exit time, no transmission will take
place.
Remember that the 1st user code is the master code and
that the 16th code may be the temporary or maid's code.
The 16th user code can be converted to a normal code
using one of the options in section [18].
When the system has been armed using "Quick Arm" [Q][0]
or "Auto-arm" (see [Q][6] "Keypad Commands"), the 1st
reporting code (reporting code for master code) will be
transmitted. The master code is required to enable or
disable these functions.
When the system is armed with one or more zones
bypassed (see [Q][1] command for zone bypassing), the
monitoring station can be notified by programming the
Partial Arm reporting in section [15]. Note that the Partial
Closing code is sent in tandem with the regular closing code
to identify it as a partial closing condition.
[12] Reporting Codes for Closing
(Arming) with Access Codes 9 to 16
See section [11] for further information.
[13] Reporting Codes for Opening
(Disarming) with Access Codes 1 to 8
The 8 reporting codes correspond to the first 8 user access
codes which are programmed using the [Q][5] command.
When the system is disarmed using one of the access
codes, the corresponding reporting code in this section is
transmitted.
See section [11] for an example of "Opening and Closing"
reporting code programming.
16