DSC Power632 Installation Manual page 35

Hide thumbs Also See for Power632:
Table of Contents

Advertisement

[002] Zone 9-16 Definitions
Default
00
Zone 9
I_______I_______I
00
Zone 10
I_______I_______I
00
Zone 11
I_______I_______I
00
Zone 12
I_______I_______I
[003] Zone 17-24 Definitions
Default
00
Zone 17
I_______I_______I
00
Zone 18
I_______I_______I
00
Zone 19
I_______I_______I
00
Zone 20
I_______I_______I
[004] Zone 25-32 Definitions
Default
00
Zone 25
I_______I_______I
00
Zone 26
I_______I_______I
00
Zone 27
I_______I_______I
00
Zone28
I_______I_______I
[005] System Times
Default
Valid entries: [001-255]
030
I_______I_______I_______I
045
I_______I_______I_______I
120
I_______I_______I_______I
004
I_______I_______I_______I
[006] Installer's Code
(Section 4.1 "Installer's Programming" )
Default
5555
I_______I_______I_______I_______I
[007] Master Code
(Section 5.1 "Programming Security Codes" )
Default
1234
I_______I_______I_______I_______I
[008] Maintenance Code
Default
AAAA
I_______I_______I_______I_______I
[009] PGM Output Programming (PGM 1 and 2)
Programmable Output Options
01 Burglary and Fire Bell Output
02 For Future Use
03 Sensor Reset
04 2-wire smoke (50/300 only)
05 System Armed Status
06 Ready To Arm
07 Keypad Buzzer Follow Mode
08 Courtesy Pulse
09 System Trouble Output (with Trouble Options)
10 System Event [Strobe (with Event Options)]
11 System Tamper (all Sources: Zones, Keypads, Modules)
12 TLM and Alarm
13 Kissoff Output
NOTE:
Output types [03], [04] and [20] cannot be used
together on the same system.
Default
19
PGM 1
I_______I_______I
(Section 5.2 "Zone Programming" )
Default
00
I_______I_______I
00
I_______I_______I
00
I_______I_______I
00
I_______I_______I
(Section 5.2 "Zone Programming" )
Default
00
I_______I_______I
00
I_______I_______I
00
I_______I_______I
00
I_______I_______I
(Section 5.2 "Zone Programming" )
Default
00
I_______I_______I
00
I_______I_______I
00
I_______I_______I
00
I_______I_______I
Entry Delay 1 (in seconds)
Entry Delay 2 (in seconds)
Exit Delay (in seconds)
(Section 5.18 "Entry/Exit Delay Options" )
Bell Cut-off (in minutes)
(Section 5.13 "Bell" )
(Section 5.1 "Programming Security Codes" )
(Section 5.11 "PGM Output Options" )
Default
10
I_______I_______I
P r o g r a m m i n g
Zone 13
Zone 14
Zone 15
Zone 16
Zone 21
Zone 22
Zone 23
Zone 24
Zone 29
Zone 30
Zone 31
Zone 32
(Section 5.18 "Entry/Exit Delay Options" )
(Section 5.18 "Entry/Exit Delay Options" )
14
Ground Start Pulse
15
Remote Operation (DLS-1 Support)
16
LINKS1000 Support (PGM1 only)
17
Away Armed Status
18
Stay Armed Status
19
Command Output #1 ([*][7][1])
20
Command Output #2 ([*][7][2])
21
Command Output #3 ([*][7][3])
22
Command Output #4 ([*][7][4])
23
Silent 24 Hour (PGM2 Only)
24
Audible 24 Hour (PGM2 Only)
PGM 2
Program PGM Option Attributes in sections [141] & [142].
W o r k s h e e t s
31

Hide quick links:

Advertisement

Table of Contents
loading