After adjusting the stitch length, fix it firmly by tightening the feed rocker link shaft screw
(The left screw
of the bed is to prevent oil leakage so tighten it firmly.)
After adjusting the needle guard(back)
9) DIFFERENTIAL FEED ADJUSTMENT
To adjust the differential feed dog, rotate the differential feed
operating lever
to the left or the right.
If the differential feed operating lever
momentums of the main feed dog and the differential feed dog
will be the same.
For the forward differential, turn the differential feed operating
lever
to the scale of 9. For the reverse differential, turn the
differential feed operating lever
28
to the proper position and tighten the needle guard(back) clamp screw
is on the 4 or 5, the
to the scale of 1.
then fill the left screw
of the bed.
firmly.