BDVR Series Direct Vent Gas Fireplace
Flame & Temperature Adjustment
RN/RP & EN/EP Models
For units equipped with "HI/LO" valves the flame
adjustment is accomplished by rotating the "HI/LO"
adjustment knob located near the center of the gas
control valve. (Figs. 42 & 43)
Honeywell Valve
Turn
counterclockwise
to decrease
flame height
Fig. 42 Flame adjustment knob for Honeywell valve.
SIT 820 Valve
Turn
counterclockwise
to increase
flame height
Fig. 43 Flame adjustment knob for SIT valve.
Flame Characteristics
It is important to periodically perform a visual check of
the pilot and burner flames. Compare them to the
illustrations. (Figs. 44-48)
If the flame patterns appear abnormal contact a
qualified service provider for service and adjustment.
3/8" - 1/2"
Fig. 44 Correct pilot flame appearance.
24
Turn clockwise
to increase
flame height
Turn clockwise
to decrease
flame height
SIT Top Convertible
SIT
SIT EN/EP
FP1229
Fig. 45 Correct burner flame appearance for 33BDVR.
Fig. 46 Correct burner flame appearance for 36BDVR.
Fig. 47 Correct burner flame appearance for 39BDVR.
Fig. 48 Correct burner flame appearance for 43BDVR.
LG271
LG272
LG273
LG274
10003357