Flame & Temperature Adjustment; Flame Characteristics - Majestic Chateau DVT38 Installation Instructions And Homeowner's Manual

Direct vent decorative gas appliance
Table of Contents

Advertisement

Vermont Castings, Majestic Products Chateau™
Flame & Temperature Adjustment
RN/RP & EN/EP Models
For units equipped with 'HI/LO' valves the flame
adjustment is accomplished by rotating the 'HI/LO'
adjustment knob located near the center of the gas
control valve. (Fig. 49)
SIT 820 Valve
Turn
counterclockwise
to increase
flame height
Fig. 49 Flame adjustment knob for SIT valve.

Flame Characteristics

It is important to periodically perform a visual check of
the pilot and burner flames. Compare them to the
illustratrations below. (Figs. 50, 51, 52)
If the flame patterns appear abnormal contact a
qualified service provider for service and adjustment.
SIT EN/EP
SIT Top Convertible
3/8" - 1/2"
Fig. 50 Correct pilot flame appearance.
24
Turn clockwise
to decrease
flame height
FP1229a
Fig. 51 DVT44 burner flame pattern.
Fig. 52 DVT38 burner flame pattern.
LG290
LG316
20006081