Your fireplace is approved to be vented either through
the side wall, or vertically through the roof.
Only venting components specifically approved and
labelled for this fireplace may be used.
Vent terminations shall not be recessed into a wall
or siding.
Horizontal venting must be installed on a level
plane without any incline or decline.
There must not be any obstruction such as bushes,
garden sheds, fences, decks or utility buildings within
24" (610mm) from the front of the termination hood.
10003357
BDVR Series Direct Vent Gas Fireplace
General Venting
Do not locate termination hood where excessive snow
or ice build up may occur. Be sure to check vent
termination area after snow falls, and clear to prevent
accidental blockage of venting system. When using
snow blowers, make sure snow is not directed towards
vent termination area.
Location of Vent Termination
It is imperative the vent termination be located observ-
ing the minimum clearances as shown on the next
page.
*Check with local codes or in absence of same with
CSAB149.1 Installation Codes (1991) for Canada or
follow the current National Fuel Gas Code, ANSI
Z223.1/NFPA 54 for installations in the USA.