Majestic 400DVB Installation Instructions Manual

Dvb series direct vent gas fireplace
Table of Contents

Advertisement

DVB Direct Vent Gas Fireplace
Models:
300DVB, 400DVB,
500DVB, 600DVB
WARNING
IF the INFoRMAtIoN IN these INstRuctIoNs Is Not
FolloWeD exActly, A FIRe oR explosIoN MAy
Result cAusING pRopeRty DAMAGe, peRsoNAl
INjuRy oR loss oF lIFe.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WhAt to Do IF you sMell GAs
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
WARNING: Improper installation, adjustment, alteration,
services or maintenance can cause injury or property
damage. Refer to this manual. For assistance or additional
information consult a qualified installer, service agency
or the gas supplier.
this appliance may be installed in an aftermarket*,
permanently located, manufactured home (usA only) or
mobile home, where not prohibited by local codes.
this appliance is only for use with the type of gas
indicated on the rating plate. this appliance is not
convertible for use with other gases, unless a certified
kit is used.
* Aftermarket: completion of sale, not for purpose of resale, from the
manufacturer.
Due to hIGh teMpeRAtuRes, the ApplIANce
540701
shoulD Be locAteD out oF tRAFFIc AND
DVB cover
AWAy FRoM FuRNItuRe AND DRApeRIes.
chIlDReN AND ADults shoulD Be AleRteD
to t h e h A Z A R D s o F h I G h s u R FA c e
teMpeRAtuRe AND shoulD stAy AWAy to
AVoID BuRNs oR clothING IGNItIoN.
youNG chIlDReN shoulD Be supeRVIseD
WheN they ARe IN the sAMe RooM As the
ApplIANce.
clothING oR otheR FlAMMABle MAteRIAl
shoulD Not Be plAceD oN oR NeAR the
ApplIANce.
Keep the RooM AReA cleAR AND FRee FRoM
coMBustIBle MAteRIAls, GAsolINe, AND
otheR FlAMMABle VApoRs AND lIquIDs.
INstAlleR: leave this manual with the appliance.
coNsuMeR: Retain this manual for future refer-
ence.
54D0701 2/09 Rev. 13

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 400DVB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Majestic 400DVB

  • Page 1 DVB Direct Vent Gas Fireplace Models: 300DVB, 400DVB, 500DVB, 600DVB WARNING IF the INFoRMAtIoN IN these INstRuctIoNs Is Not FolloWeD exActly, A FIRe oR explosIoN MAy Result cAusING pRopeRty DAMAGe, peRsoNAl INjuRy oR loss oF lIFe. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    coNteNts DVB Series Direct Vent Gas Fireplace Important safety Information ........3 operating Instructions (electronic) ....... 37 product Features ............5 checking Gas pressure - (signature command system) ......38 code Approval ............5 electrical Wiring pre-Installation Information (signature command system) ......38 High Elevations .............
  • Page 3: Dvb Series Direct Vent Gas Fireplace

    DVB Series Direct Vent Gas Fireplace IMpoRtANt sAFety INFoRMAtIoN oWNeR INstAlleR Please retain these instructions for future reference. Please leave these instructions with the appliance. • Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. •...
  • Page 4 DVB Series Direct Vent Gas Fireplace IMpoRtANt sAFety INFoRMAtIoN 12. Do not use this fireplace to cook food or burn paper IMpoRtANt: or other objects. pleAse ReAD the FolloWING 13. Never place anything on top of fireplace. cAReFully 14. Do not use any solid fuels (wood, coal, paper, card- board, etc.) in this fireplace.
  • Page 5: Product Features

    pRoDuct FeAtuRes and coDe AppRoVAl DVB Series Direct Vent Gas Fireplace PRODUCT SPECIFICATIONS • This appliance has been certified for use with either natural or propane gas. Refer to appropriate data plates. • This appliance is not for use with solid fuels. •...
  • Page 6: Pre-Installation Information

    pRe-INstAllAtIoN INFoRMAtIoN DVB Series Direct Vent Gas Fireplace hIGh eleVAtIoNs Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370 m) above sea level. For elevations above 4,500 feet (1,370 m) in USA, installation must be in accor- dance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdic- tion.
  • Page 7: Fireplace Dimensions

    FIReplAce DIMeNsIoNs DVB Series Direct Vent Gas Fireplace 1/2” 5/8” 1/2” 5/8” 5/8" 1/2” 1/2” 5/8" 3 ” 8 ” Item Description 300DVB 400DVB 500DVB 600DVB Overall Front Width 33Z\zn” 37Z\zn” 41Z\zn” 47Z\zn” 540701 Inside Width 29M\,” 32” 36” 42”...
  • Page 8: Fireplace Framing

    FIReplAce FRAMING DVB Series Direct Vent Gas Fireplace FIReBox FRAMING Firebox framing can be built before or after the appliance is set in place. Construct firebox framing following Figure 2 and the chart below for your specific installation requirements. See Figure 3 on page 8 for firebox dimensions.
  • Page 9: Fireplace Location

    DVB Series Direct Vent Gas Fireplace FIReplAce locAtIoN FIReplAce locAtIoN colD clIMAte INsulAtIoN Plan for the installation of your appliance. This If you live in a cold climate, seal all cracks includes determining where the unit is to be installed, around your appliance, and wherever cold air the vent configuration to be used, framing and finish- could enter the room, with noncombustible...
  • Page 10: Clearances

    cleARANces DVB Series Direct Vent Gas Fireplace cleARANces to coMBustIBles Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. the appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.
  • Page 11: Secure Fireplace To Floor Or Framing

    secuRe FIReplAce to FlooR or FRAMING DVB Series Direct Vent Gas Fireplace The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing.
  • Page 12: Installation Information

    DVB Series Direct Vent Gas Fireplace INstAllAtIoN INFoRMAtIoN FINIshING MAteRIAl Note: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to final finishing to avoid costly reconstruction. Never obstruct or modify the air inlet or outlet grilles (louvers).
  • Page 13: Vent Installation

    VeNt INstAllAtIoN DVB Series Direct Vent Gas Fireplace horizontal sections of this vent system this fireplace must be vented to the require a minimum of 3” clearances outside. the venting system must to combustibles at the top of the flue NeVeR be attached to a chimney and 1”...
  • Page 14: Optional Top Vent Installation

    VeNt INstAllAtIoN DVB Series Direct Vent Gas Fireplace optIoNAl top VeNt ApplIcAtIoN After conversion to top vent configuration, The appliance is shipped as a rear vent unit. If the instal- the 4” (102 mm) flue pipe should be lation layout requires the unit to be a top vent configu- concentric within the 6B\,”...
  • Page 15: Installation Planning

    VeNt INstAllAtIoN DVB Series Direct Vent Gas Fireplace INstAllAtIoN plANNING Never run the vent pipe down. this may There are two basic types of direct-vent installation: cause excessive temperatures which could • Horizontal Termination cause a fire. • Vertical Termination It is important to select the proper length of vent pipe for the type of termination you choose.
  • Page 16: For Horizontal Termination

    VeNt INstAllAtIoN DVB Series Direct Vent Gas Fireplace FoR hoRIZoNtAl teRMINAtIoN Inside corner Detail Fixed Closed Opera- Fixed Closed Operable Vent Terminal Area Where Terminals Air Supply Inlet are Not Permitted Figure 11 - Horizontal Vent Termination Location MINIMuM DIstANces A = Clearance above the grade, a veranda, porch, deck, or balcony [*12"...
  • Page 17: How To Use The Vent Graph

    VeNt INstAllAtIoN DVB Series Direct Vent Gas Fireplace teRMINAtIoN cleARANces FoR BuIlDINGs WIth coMBustIBle AND NoNcoMBustIBle exteRIoRs G=6" (152mm) F=6" (152mm) Inside Corner  Outside Corner  C = Maximum depth of 48" (1219mm)     for alcove location D = Minimum width for back wall of     alcove location     Combustible - 38" (965mm)     Noncombustible - 24" (610mm) E = Clearance from corner in alcove  Combustible &      location Noncombustible  ...
  • Page 18: Rear (Through-The-Wall) Applications

    DVB Series Direct Vent Gas Fireplace VeNt INstAllAtIoN ReAR (thRouGh the WAll) ApplIcAtIoNs When installed as a rear vent unit this appliance may be vented directly to a termination located on the rear wall behind the appliance • The maximum horizontal distance between the rear of the appliance and the outside of termination is 20"...
  • Page 19: Rear Wall Vent Installation

    DVB Series Direct Vent Gas Fireplace VeNt INstAllAtIoN ReAR WAll VeNt INstAllAtIoN (continued) 4. Apply a bead of non-hardening mastic around the outside edge of vent cap. Position the vent cap in the center of hole on the exterior wall with the word “UP” on the vent cap facing up.
  • Page 20: Horizontal Termination Configurations

    VeNt INstAllAtIoN DVB Series Direct Vent Gas Fireplace hoRIZoNtAl teRMINAtIoN coNFIGuRAtIoNs since it is very important that the venting system maintain its bal- ance between the combustion air intake and the flue gas exhaust, certain limitations as to vent configurations apply and must be Dimensions in ...
  • Page 21: Horizontal Termination Configuration

    VeNt INstAllAtIoN DVB Series Direct Vent Gas Fireplace hoRIZoNtAl teRMINAtIoN coNFIGuRAtIoN (Continued) • If a 90° elbow is used in the horizontal vent run (level height maintained) the horizontal vent length is reduced by 36". Figures 90° 21 and 22. This does not apply if the 90° elbows are used to increase or redirect a vertical rise.
  • Page 22: Below Grade Installation

    DVB Series Direct Vent Gas Fireplace VeNt INstAllAtIoN BeloW GRADe INstAllAtIoNs When it is not possible to meet the required vent terminal clearances of 12" above grade level, a snorkel kit is recommended. It allows installation depth down to 7" (178 mm) below grade level. The 7"...
  • Page 23: Vertical Through-The-Roof Applications

    VeNt INstAllAtIoN DVB Series Direct Vent Gas Fireplace VeRtIcAl (thRouGh-the-RooF) ApplIcAtIoNs This Gas Fireplace has been approved for, • Vertical installations up to 40' (12 m) in height. Up to a 10' (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows. Figure 28 Note: Horizontal sections of this vent system require a minimum of 3"...
  • Page 24: Installation For Vertical Termination

    DVB Series Direct Vent Gas Fireplace VeNt INstAllAtIoN INstAllAtIoN FoR VeRtIcAl teRMINAtIoN 1. Determine the route your vertical venting will take. If ceiling joist, Roof Flashing roof rafters or other framing will obstruct the venting system, con- sider an offset. Refer to Figure 30 to avoid cutting load bearing members.
  • Page 25: Cathedral Ceiling Installation

    VeNt INstAllAtIoN DVB Series Direct Vent Gas Fireplace 4. Connect a section of pipe and extend up through the hole. NOTE: If an offset is needed to avoid obstructions, you must support the vent pipe every three (3) feet. Use wall straps for this purpose. Refer to Page 23, Figure 28. Whenever possible, use 45°...
  • Page 26: Flex Vent Installation

    Flex VeNt INstAllAtIoN DVB Series Direct Vent Gas Fireplace 1. Flexible UL1777 listed venting may be used in any venting application where rigid direct vent compo- nents can be used. All restrictions, clearances and allowances that pertain to the rigid piping apply to the flexible venting.
  • Page 27 Flex VeNt INstAllAtIoN DVB Series Direct Vent Gas Fireplace C. Routing UL1777 flex pipe. 1. Always maintain the required clearance when routing the flex vent assembly. 2. Install firestop spacers (Figure 36) when penetrating ceiling, attic spaces, or walls. 3. Do not allow the flexible vent to bend in radius tighter than 5" (127 mm). Figure 35 4.
  • Page 28: Fireplace Installation

    DVB Series Direct Vent Gas Fireplace FIReplAce INstAllAtIoN checK GAs type Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or conversion kit.
  • Page 29 DVB Series Direct Vent Gas Fireplace FIReplAce INstAllAtIoN A manual shutoff valve must be installed only persons licensed to work with gas upstream of the appliance. union tee piping may make the necessary gas and plugged 1/8” Npt pressure tapping connections to this appliance.
  • Page 30: Checking Gas Pressure (Millivolt)

    DVB Series Direct Vent Gas Fireplace MIllIVolt & electRoNIc checK GAs pRessuRe and electRIcAl INstAllAtIoN 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is different from the fireplace, STOP! Do not install the appliance.
  • Page 31: Electrical Installation

    electRIcAl INstAllAtIoN DVB Series Direct Vent Gas Fireplace ReMote WAll MouNteD sWItch A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 42. Do not extend beyond the wall switch wire length provided.
  • Page 32: Electronic Pilot Ignition Wiring

    electRIcAl INstAllAtIoN DVB Series Direct Vent Gas Fireplace electRoNIc pIlot IGNItIoN WIRING Do not connect 110-120V Ac to the Remote Wall switch. the appliance will malfunction. To Junction Box  Pilot Assembly  GREEN Ignition Module Spark WHITE BLACK Sense Electronic Valve  RED #2  BLACK WHITE Primary - 120V  GRAY #1 RED #2 ...
  • Page 33: Optional Fan/Blower Systems (Milli-Volt)

    DVB Series Direct Vent Gas Fireplace optIoNAl FAN / BloWeR systeM optIoNAl FAN/BloWeR systeMs (Blot) The junction box for the fan/blower systems has been factory installed. This system requires that 110-120 VAC to be wired to the factory installed junction box before the fireplace is permanently installed.
  • Page 34: Operating Instructions (Millivolt)

    opeRAtING INstRuctIoNs (MIllIVolt) DVB Series Direct Vent Gas Fireplace FoR youR sAFety ReAD BeFoRe lIGhtING If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with a pilot which must be lit with built-in piezo ignitor while following these instructions exactly.
  • Page 35: Lighting Pilot

    opeRAtING INstRuctIoNs (MIllIVolt) DVB Series Direct Vent Gas Fireplace lIGhtING pIlot FoR the FIRst tIMe AppRoVeD leAK testING MethoD If using a soap and water You may check for gas leaks with the following methods solution to test for leaks, only: Do Not spray solution onto •...
  • Page 36: Lighting Burner

    DVB Series Direct Vent Gas Fireplace opeRAtING INstRuctIoNs (MIllIVolt) lIGhtING BuRNeR MAIN BuRNeR sWItch The “ON/OFF/RS” switch for the main burner can be found behind door of the fireplace. This switch allows you to turn on and to turn off the main burner without using the gas valve knob. Make sure the button is in the “ON”...
  • Page 37: Operating Instructions (Electronic)

    opeRAtING INstRuctIoNs (electRoNIc) DVB Series Direct Vent Gas Fireplace FoR youR sAFety ReAD BeFoRe lIGhtING This appliance is equipped with an ignition device If you do not follow these (Piezo) which automatically lights the pilot. Do NOT instructions exactly, a fire or try to light the burner by hand.
  • Page 38: Checking Gas Pressure - (Signature Command System)

    DVB Series Direct Vent Gas Fireplace sIGNAtuRe coMMAND - checK GAs pRessuRe and electRIcAl INstAllAtIoN 1. Check gas type. The gas supply must be the same as Pressure Inlet stated on the appliance’s rating decal. If the gas supply is different from the fireplace, stop! Do not install the appliance.
  • Page 39: Command Center Wall Installation

    DVB Series Direct Vent Gas Fireplace sIGNAtuRe coMMAND - electRIcAl INstAllAtIoN OPTIONAL AC BOX TO JUNCTION BOX IN FIREPLACE PILOT OPTIONAL LIGHT WHITE BLACK OPTIONAL WHITE BLOWER BLACK BLACK OPTIONAL WHITE GREEN CONNECTOR PIN TO CONTROL BOX INPUT 300 WATT MAX EACH RF RECEIVER ON/OFF BUTTON CONTROL BOX...
  • Page 40: Optional Fan/Blower System

    optIoNAl FAN BloWeR systeM DVB Series Direct Vent Gas Fireplace optIoNAl FAN/BloWeR systeM (Blotsc) Installation Instructions Wiring 120V AC 1. Before installing the blower, wire the receptacle into an 60Hz electrical circuit. This should be done before framing the fireplace. Wire with minimum 60° C wire in accordance with Factory Supplied prevailing codes.
  • Page 41 optIoNAl FAN BloWeR systeM DVB Series Direct Vent Gas Fireplace 7. Secure the AC box to the control box using Screw screw provided. Figure 56 Ac Box 8. Plug in wiring harness to the back of AC box. 9. Connect the blower according to the wiring diagram.
  • Page 42: Operating Instructions (Signature Command System)

    DVB Series Direct Vent Gas Fireplace opeRAtING INstRuctIoNs - sIGNAtuRe coMMAND FoR youR sAFety ReAD BeFoRe lIGhtING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of lie. A.
  • Page 43: Operating Instructions

    DVB Series Direct Vent Gas Fireplace opeRAtING INstRuctIoNs - sIGNAtuRe coMMAND opeRAtING INstRuctIoNs 1. stop! Read the safety information above. 2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 3.
  • Page 44: Signature Command System Operation

    sIGNAtuRe coMMAND systeM opeRAtIoN INstRuctIoNs DVB Series Direct Vent Gas Fireplace FeAtuRes To Thermopile RF Receiver ON/OFF To Sensor command center To Sparker • Easy Access Function Operation and System Configu- ration NG/LP • Operation Confirmation/Fault Diagnostic Indications Conversion (LED/Buzzer) •...
  • Page 45: System Configuration/Setup

    sIGNAtuRe coMMAND systeM opeRAtIoN INstRuctIoNs DVB Series Direct Vent Gas Fireplace systeM coNFIGuRAtIoN/setup System configuration/setup is done on the Command Center. Intermittent/standing pilot setup (Default intermittent) 1. Holding the ON button on the Command Center while turning on the master switch will toggle between standing pilot and intermittent pilot.
  • Page 46 sIGNAtuRe coMMAND systeM opeRAtIoN INstRuctIoNs DVB Series Direct Vent Gas Fireplace FuNctIoNs/opeRAtIoN turning on the fireplace 1. Turn on the master switch and wait for a beep. 2. Press the ON button on the Command Center. Pilot will light and burner will come on High setting. pilot safety lockout Function 1.
  • Page 47: Glass Removal

    GlAss ReMoVAl DVB Series Direct Vent Gas Fireplace GlAss FRAMe ReMoVAl 1. Release two clamps on bottom of fireplace. Figure 59 2. Tilt glass frame out and lift glass frame up until it clears three tabs on top of fireplace. 3.
  • Page 48: Final Installation

    Do not sprinkle the lava rock or ember chunks on top of the burner. this may cause potential sooting, glass breakage and a fire Center Vertical Grate Bar hazard LG607 Figure 61 - Right Vertical Grate Bar Log Placement (300DVB & 400DVB Shown) LG607 54D0701 DVB logs...
  • Page 49: Cleaning And Maintenance

    DVB Series Direct Vent Gas Fireplace cleANING and MAINteNANce turn off gas before servicing fireplace. It is recommended that a qualified service Thermocouple technician perform these check-ups at the Thermopile beginning of each heating season. BuRNeR, pIlot AND coNtRol coMpARtMeNt Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year.
  • Page 50: Vent System

    cleANING and MAINteNANce DVB Series Direct Vent Gas Fireplace VeNt systeM The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow.
  • Page 51: Troubleshooting

    tRouBleshootING DVB Series Direct Vent Gas Fireplace stANDING pIlot IGNItIoN syMptoM possIBle cAuse ActIoN 1. Spark ignitor will A. Wire disconnected. A. Open door and check to make sure wire is connected not light pilot after to ignitor. repeated triggering of B.
  • Page 52 tRouBleshootING DVB Series Direct Vent Gas Fireplace stANDING pIlot IGNItIoN syMptoM possIBle cAuse ActIoN 4. Frequent pilot A. Pilot flame may be too high A. Clean and adjust the pilot flame for maximum flame outage problem. or too low, causing pilot impingement on thermocouple.
  • Page 53: Signature Command System

    tRouBleshootING DVB Series Direct Vent Gas Fireplace sIGNAtuRe coMMAND systeM ACTION OPERATION FAULT DIAGNOSIS Using Battery polarity wrong? Re-install batteries battery? Make sure Command Install batteries and/or Battery voltage low? Change batteries Center and plug in the AC board No beep in about the control 8 seconds board are...
  • Page 54: Replacement Parts

    ReplAceMeNt pARts DVB Series Direct Vent Gas Fireplace FIReBox coMpoNeNts 540701 DVB parts 54D0701...
  • Page 55 ReplAceMeNt pARts DVB Series Direct Vent Gas Fireplace FIReBox coMpoNeNts Item Description qty. 300DVB 400DVB 500DVB 600DVB standard Features Junction Box 26D2128K 26D2128K 26D2128K 26D2128K Black Louver 54D0246 26D0695 26D0697 26D0699 Glass Frame Assembly 54D0294 54D0340 54D0195 54D0443 Factory Installed options...
  • Page 56: Standing Pilot Millivolt Control

    ReplAceMeNt pARts DVB Series Direct Vent Gas Fireplace stANDING pIlot - MIllIVolt coNtRol 11,12,13,14 540701 DVB millivolt parts 54D0701...
  • Page 57 ReplAceMeNt pARts DVB Series Direct Vent Gas Fireplace stANDING pIlot - MIllIVolt coNtRol Item Description qty. 300DVBNV 300DVBpV 400DVBDNV 400DVBpV 500DVBNV 500DVBpV 600DVBNV 600DVBpV Gas Valve Assy. 37D0117 37D0118 37D0117 37D0118 37D0117 37D0118 37D0117 37D0118 Pilot Assembly 37D0018 37D0019 37D0018 37D0019 37D0018 37D0019...
  • Page 58: Electronic Ignition

    ReplAceMeNt pARts DVB Series Direct Vent Gas Fireplace electRoNIc IGNtIoN 540701 DVB elect parts 54D0701...
  • Page 59 ReplAceMeNt pARts DVB Series Direct Vent Gas Fireplace electRoNIc IGNtIoN Item Description qty. 300DVBNe 300DVBpe 400DVBNe 400DVBpe 500DVBNe 500DVBpe 600DVBNe 600DVBpe 1. Gas Valve Assy. 37D0016 37D0017 37D0016 37D0017 37D0016 37D0017 37D0016 37D0017 2. Pilot Assembly 37D0020 37D0021 37D0020 37D0021 37D0020 37D0021 37D0020...
  • Page 60: Signature Command System

    ReplAceMeNt pARts DVB Series Direct Vent Gas Fireplace sIGNAtuRe coMMAND systeM 13, 14, 15 540701 SC parts 54D0701...
  • Page 61 ReplAceMeNt pARts DVB Series Direct Vent Gas Fireplace sIGNAtuRe coMMAND systeM Item Description qty. 300DVBNs 300DVBps 400DVBNs DVB400ps 500DVBNs 500DVBps 600DVBNs 600DVBps 1. Gas Valve Assy. 80D0001 80D0002 80D0001 80D0002 80D0001 80D0002 80D0001 80D0002 2. Pilot Assembly 80D0006 80D0007 80D0006 80D0007 80D0006 80D0007...
  • Page 62: Vent Components

    DVB Series Direct Vent Gas Fireplace ReplAceMeNt pARts VeNt coMpoNeNts 540701 DVB vent components 54D0701...
  • Page 63 ReplAceMeNt pARts DVB Series Direct Vent Gas Fireplace VeNt coMpoNeNts current simpson simpson Duravent Duravent qty./ or Mhsc or Mhsc selkirk Item Description part no. part no. part no. Side Wall Flexible Pipe Termination Kit BHSFTKA BHSFTK Includes termination cap with built-in vinyl siding standoff, heat deflector, firestop, 20"...
  • Page 64: Logs

    ReplAceMeNt pARts DVB Series Direct Vent Gas Fireplace loGs Ref. Description qty. 300DVB 400DVB 500DVB 600DVB 1. Rear Log 54D0122 54D0117 54D0331 54D0331 2. Left Log 54D0123 54D0118 54D0358 54D0358 3. Right Log 54D0124 54D0119 54D0359 54D0359 4. Center Log...
  • Page 65: Mass Residents Only

    MAssAchusetts ResIDeNts oNly: Notes DVB Series Direct Vent Gas Fireplace pleAse ReAD AND FolloW these specIAl RequIReMeNts Note ReGARDING VeNteD pRoDucts This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. Any residence with a direct vent product must have a CO detector installed in the residence.
  • Page 66 specIAl RequIReMeNts coNtINueD DVB Series Direct Vent Gas Fireplace 2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. 3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent termi- nal for the horizontally vented gas fueled heating appliance or equipment.
  • Page 67: Lifetime Warranty

    DVB Series Direct Vent Gas Fireplace lIMIteD lIFetIMe WARRANty polIcy lIFetIMe WARRANty The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. FIVe yeAR WARRANty The following components are warranted five (5) years to the original owner, subject of proof of purchase: Ceramic Fiber Logs.
  • Page 68: Energuide

    efficiency Ratings Model enerGuide Ratings Fireplace efficiency (%) 300DVBNV 57.9 300DVBPV 53.8 300DVBNE 61.8 300DVBPE 55.7 400DVBNV 58.4 400DVBPV 58.5 400DVBNE 61.1 400DVBPE 60.7 500DVBNV 58.7 500DVBPV 58.8 500DVBNE 61.3 500DVBPE 60.8 600DVBNV 58.4 600DVBPV 58.5 600DVBNE 60.9 600DVBPE 60.5 Mhsc 149 Cleveland Drive •...

This manual is also suitable for:

300dvb500dvb600dvb

Table of Contents