Removal Of Outdoor Fan / Fan Motor - Daikin 2MKS40G2V1B Service Manual

Inverter multi for 2 rooms g-series
Hide thumbs Also See for 2MKS40G2V1B:
Table of Contents

Advertisement

Outdoor Unit
1.5

Removal of Outdoor Fan / Fan Motor

Procedure
Step
1. Remove the outdoor fan.
1
Remove the washer
fitted nut.
Remove the outdoor
2
fan.
2. Remove the fan motor.
Disconnect the
1
connector for the fan
motor [S70].
287
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
[S70]
Points
Nut size: M6
(R7618)
(R7619)
When reassembling, align
mark of the outdoor fan
with D-cut section of the
motor shaft.
(R7620)
(R7621)
Removal Procedure
SiBE12-816_D
10 mm
(R12236)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents