Function of Indoor Unit (SA Models)
2.2

Thermostat Sensor in Remote Controller

Temperature is controlled by both the thermostat sensor in remote controller and air suction
thermostat in the indoor unit. (This is however limited to when the field setting for the thermostat
sensor in remote controller is set to "Use".)
Cooling
If there is a significant difference in the set temperature and the suction temperature, fine
adjustment control is carried out using a body thermostat sensor, or using the sensor in the
remote controller near the position of the user when the suction temperature is near the set
temperature.
Set temperature
(Ts)
(This example also assumes there are several other air conditioners, and the suction
temperature changes even when the thermostat sensor is off.)
Body thermostat sensor is used for temperatures from 18°C to 23°C (A → C).
Remote controller thermostat sensor is used for temperatures from 23°C to 27°C (C → E).
Body thermostat sensor is used for temperatures from 27°C to 30°C (E → F).
Body thermostat sensor is used for temperatures from 30°C to 25°C (F → D).
Remote controller thermostat sensor is used for temperatures from 25°C to 21°C (D → B).
Body thermostat sensor is used for temperatures from 21°C to 18°C (B → A).
75
A
Range in which thermostat sensor
in remote controller can be used
Assuming the set temperature in the figure above is 24°C, and the suction
temperature has changed from 18°C to 30°C (A → F):
Assuming suction temperature has changed from 30°C to 18°C (F → A):
TH1 = Ts - 1
TH1 = Ts - 3
B
C
D
Range in which body
thermostat sensor can
be used
TH1 = Ts + 3
E
F
Suction temperature (TH1)
Differential
Function and Control
SiBE12-816_D
TH1 = Ts + 1