SA Indoor Unit - FFQ Series
The setting temperature range of the remote
controller is 16°C to 32°C.
VRV System
See the operation manual provided with the
air conditioner.

5. OPERATION PROCEDURE

Refer to figure 1 on page [1]
Operating procedure varies with heat
pump type and cooling only type. Contact
your Daikin dealer to confirm your system
type.
To protect the unit, turn on the main power
switch 6 hours before operation.
If the main power supply is turned off
during operation, operation will restart
automatically after the power turns back
on again.
COOLING, HEATING, AUTOMATIC,
FAN, AND PROGRAM DRY
OPERATION
Operate in the following order.
AUTOMATIC OPERATION can be
selected only by Heat pump split system.
For cooling only type, "COOLING", and
"FAN" and "DRY" operation are able to
select.
〈〈FOR SYSTEMS WITHOUT COOL/
HEAT CHANGEOVER REMOTE
CONTROL SWITCH〉〉
Refer to figure 1-1, 2 on page [1]
1
Press OPERATION MODE SELECTOR
button several times and select the
OPERATION MODE of your choice as
follows.
COOLING OPERATION................... "
HEATING OPERATION.................... "
7
187
OPERATION MODE
SELECTOR
AUTOMATIC OPERATION................"
In this operation mode, COOL/HEAT
changeover is automatically conducted.
FAN OPERATION............................. "
DRY OPERATION ............................."
The function of this program is to
decrease the humidity in your room with
the minimum temperature decrease.
Micro computer automatically
determines TEMPERATURE and FAN
SPEED.
This system does not go into operation if
the room temperature is below 16˚C.
ON/OFF
2
Press ON/OFF button
OPERATION lamp lights up or goes off and
the system starts or stops OPERATION.
NOTE
Do not turn OFF power immediately after
the unit stops. Then, wait no less than 5
minutes.
Water is leaking or there is something else
wrong with the unit.
〈〈FOR SYSTEMS WITH COOL/HEAT
CHANGEOVER REMOTE CONTROL
SWITCH〉〉
Refer to figure 1-1,3 on page [1]
OPERATION MODE
1
SELECTOR
(1)
Select OPERATION MODE with the
COOL/HEAT CHANGEOVER REMOTE
CONTROL SWITCH as follows.
COOLING OPERATION ............ "
HEATING OPERATION............. "
"
"
SiBE12-816_D
"
"
"
"
"
English
Operation Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents