Troubleshooting - Baymak Linyitomat Plus Instructions And Operating Manual

Domestic solid fuel boilers
Table of Contents

Advertisement

Trouble Shutting
Case
There is some water leak on
the boiler
Circulation pump doesn't work.
The fan doesn't work.
Check if there is any electrical power
If Electrical power was gone
63 9810.0293 - Rev.00 - 08/09/2008
Action
Apply to a Baymak authorized
service.
Check the electrical connection.
Check the circulation switch. If
doesn't work, please don't load
the fuel and call the Baymak
authorized service.
Check the electrical connection
Check the circulation switch. If it
doesn't work, don't load the fuel
and call the Baymak authorized
service.
If there is any damaged cable
shut of the electrical power.
Discharge the boiler. To have
made electrical connection by
authorized service.
Open the
by-pass valve
immediately.
Close all the doors and chimney
clamp of the boiler.
To be sure if the return and out
security lines are open, expansion
tank is not empty.
If the boiler water temperature
doesn't decrease despite of the
opening by-pass valve, pour some
sand and ash over the coal.
Don't fill cold water to the
boiler while it is working.