Functions Of The Control Panel; 9810.0293 - Rev.00 - 08/09/2008 - Baymak Linyitomat Plus Instructions And Operating Manual

Domestic solid fuel boilers
Table of Contents

Advertisement

The boiler can be operated whether automatically within electronic
thermostat control or manually with user control.
1.)For automatic control;
Switch the manuel-0-Otomatik button to otomatik position.
The electronic thermostat control is enabled in this position. It controls the
fan and pump according to the water temperature. At the start up, the
electronic thermostat control make the fan works.When the water
temperature is 40ºC, the pump starts working. When the water temperature
starts to decreasing, it stops the pump at 40ºC and stops the fan at 30ºC.
IMPORTANT: In automatic working position, minimum one of the pump
button or the fan button must be closed(0) to have a good working.
2.)For working manual operating;
Switch the manuel-0-Otomatik button to manuel position. In this position, the
fan and the pump are controlled theirself buttons.
In both position(manual or automatic), the temperature adjustment is maked
with the adjust thermostat. If the water temperature is over the set
temperature, the adjust thermostat stops the fan.

63 9810.0293 - Rev.00 - 08/09/2008