2000 M50A Engine Data: Remote Heat Exchanger, Reference Condition: Intake-Air Temperature 25 °C - MTU 8 V 2000 M50A, M50B Operating Instructions Manual

Diesel engine
Hide thumbs Also See for 8 V 2000 M50A, M50B:
Table of Contents

Advertisement

3.22 16V 2000 M50A engine data: Remote heat exchanger,
reference condition: Intake-air temperature 25 °C
Explanation
Abbrev.
Meaning
DL
Reference value: Continuous power
BL
Reference value: Fuel stop power
A
Design value
G
Guaranteed value
R
Guideline value
L
Limit value, up to which the engine can be operated, without change (e.g. of power setting)
N
Not yet defined value
-
Not applicable
X
Applicable
Reference conditions
Engine model
Application group
Intake-air temperature
Raw water inlet temperature
Barometric pressure
Site altitude above sea level
Power-related data (power ratings are net brake power to ISO 3046)
Number of cylinders
Rated engine speed
Continuous power ISO 3046 (10% overload capability, design power DIN 6280,
ISO 8528)
General conditions (for maximum power)
Number of cylinders
Intake depression (new filter)
Intake depression, max.
Model related data (basic design)
Number of cylinders
Cylinder arrangement: V angle
Bore
Stroke
Displacement of a cylinder
Displacement, total
MW15550/07E 2013-01 | Technical Data | 105
16V2000
M50A
3A
°C
25
°C
25
mbar
1000
m
100
16
A
rpm
1500
A
kW
664
16
A
mbar
15
L
mbar
50
16
Degrees
90
mm
130
mm
150
Liters
1.99
Liters
31.84

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents