7.22.5 Engine monitoring unit – Plug connection check
Preconditions
☑Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use
Connector pliers
Checking engine monitoring unit
plug connections
1.
Use connector pliers (3) to make certain
that all engine monitoring unit plug connec-
tions are securely seated.
2.
Tighten loose bayonet union nuts (2) with
connector pliers (3) by turning them clock-
wise until they lock into place.
3.
Make sure that unassigned sockets are
closed off with cover caps.
4.
If bayonet couplings are defective, contact
Service.
MW15550/07E 2013-01 | Task Description | 251
Part No.
Qty.
0135315483
1