MTU 8 V 2000 M50A, M50B Operating Instructions Manual page 154

Diesel engine
Hide thumbs Also See for 8 V 2000 M50A, M50B:
Table of Contents

Advertisement

Fault
code
078
079
080
089
090
091
092
093
094
100
101
102
103
104
105
106
154 | Troubleshooting | MW15550/07E 2013-01
Alarm text
Meaning
LIM INTERCOOLER
Alarm from external charge-air
LEV.
coolant level monitoring
L Bin-EXTERN 3
Alarm from external binary
channel 3
L Bin-EXTERN 4
Alarm from external binary
channel 4
ENGINE SPEED
Engine speed lower than 200
LOW
rpm;
automatic engine shutdown
IDLE SPEED LOW
Idle speed not reached within a
specified period;
Termination of starting proce-
dure.
RUN UP SPEED
Run-up speed not reached
LOW
within a specified period;
Termination of starting proce-
dure.
START SPEED
Starter speed not reached with-
LOW
in a specified period;
Termination of starting proce-
dure.
PREHEAT TEMP.
Coolant preheating tempera-
LIMIT2
ture too low during starting
(2nd limit)
Termination of starting proce-
dure (depending on project de-
sign)
PREHEAT TEMP.
Coolant preheating tempera-
LIMIT1
ture too low during starting (1st
limit)
EDM NOT VALID
Check sum error of measuring-
point data in EDM
IDM NOT VALID
Check sum error of measuring-
point data in IDM
INVALID FUEL
Check sum error of accumulat-
CONS. 1
ed fuel consumption data in
EDM (redundant data record 1)
INVALID FUEL
Check sum error of accumulat-
CONS. 2
ed fuel consumption data in
EDM (redundant data record 2)
OP HOURS1 NOT
Check sum error of hour meter
VALID
data in EDM
OP HOURS2 NOT
Check sum error of hour meter
VALID
data in IDM
ERR REC1 NOT
Check sum error of fault mem-
VALID
ory in EDM (redundant data re-
cord 1)
Task
(Depending on the corresponding measur-
ing point, which is read via CAN bus)
(Depending on the corresponding measur-
ing point, which is read via CAN bus)
(Depending on the corresponding measur-
ing point, which is read via CAN bus)
Re-start the engine (→ Page 144) .
Note further alarms.
Note further alarms.
Note further alarms.
Check preheating pump / preheating sys-
tem (see manufacturer's documentation).
Check preheating pump / preheating sys-
tem (see manufacturer's documentation).
If fault occurs repeatedly: Contact Service.
If fault occurs repeatedly: Contact Service.
If fault occurs repeatedly: Contact Service.
If fault occurs repeatedly: Contact Service.
If fault occurs repeatedly: Contact Service.
If fault occurs repeatedly: Contact Service.
If fault occurs repeatedly: Contact Service.