SEA FULL TANK 100 Installation Manual

SEA FULL TANK 100 Installation Manual

Hydraulic operator for swing gate

Advertisement

Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
16
Cod. 67410845
®
H Y DRAU LI C OPERATOR FOR SWI N G GAT E
FU LL TAN K
INSTALLATION MANUAL
and Security Information
Zona Ind. S.Atto
Tel. +39.0861.588341 - Fax+39.0861.588344
e-mail: seacom@seateam.com
WEB SITE : www.seateam.com
SEA S.r.l.
64020 TERAMO Italy
REV 02 - 06/2009
English
English

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FULL TANK 100 and is the answer not in the manual?

Questions and answers

Summary of Contents for SEA FULL TANK 100

  • Page 1 International registered trademark n. 804888 H Y DRAU LI C OPERATOR FOR SWI N G GAT E FU LL TAN K INSTALLATION MANUAL and Security Information SEA S.r.l. Zona Ind. S.Atto 64020 TERAMO Italy Tel. +39.0861.588341 - Fax+39.0861.588344 e-mail: seacom@seateam.com WEB SITE : www.seateam.com...
  • Page 2: Features And Specifications

    Safety Gate (device for the reading of the gate position), for reverse in case of obstacle. Fig. 1 Fig. 2 Dimensions (mm) Dimensions (mm) FULL TANK 200 FULL TANK 100 Fig. 3 1. Shaft cover 2. Release 3. Front bracket 4. Rear bracket 5.
  • Page 3 By-pass valves Shaft Cover Front bracket Release Pin rear Rear attachment attachment (short) End cover Clevis Attachment Breather screw Brass Pin (long) Fig. 4...
  • Page 4: Typical Installation

    ® FU LL TAN K Sistemi Elettronici English English di Apertura Porte e Cancelli International registered trademark n. 804888 TYPICAL INSTALLATION OUTSIDE INSIDE Full Tank operator Mechanical stop Gate 2 control board Warning lamp Photocell tx Differential switch 16A-0,03A Photocell rx Key switch start-stop Antenna 10.
  • Page 5 ® FU LL TAN K Sistemi Elettronici English English di Apertura Porte e Cancelli International registered trademark n. 804888 INSIDE OPENING INSTALLATION Total stroke 270 mm - max. recommended stroke 250 mm Max. Outside Max. Stroke Stroke Opening (mm) for 90°(mm) (mm) (mm) (mm) Angle 110°...
  • Page 6 ® FU LL TAN K Sistemi Elettronici English English di Apertura Porte e Cancelli International registered trademark n. 804888 OUTSIDE OPENING INSTALLATION Outside Total stroke 270 mm - max. recommended stroke 250 mm Max. Stroke Stroke Opening Fig. 8 max (mm) for 90°(mm) (mm) (mm) Angle...
  • Page 7: Release Mounting

    ® FU LL TAN K Sistemi Elettronici English English di Apertura Porte e Cancelli International registered trademark n. 804888 RELEASE MOUNTING Fig. 9 Remove the transporting plate as shown in Fig. 9. Fig. 10 Mount the release as shown in Fig. 10. Cod.
  • Page 8 ® FU LL TAN K Sistemi Elettronici English English di Apertura Porte e Cancelli International registered trademark n. 804888 INSTALLATION OF THE OSCILLATING REAR BRACKET ØOpen carefully the package, making sure not to loose parts which are listed in fig. 4 ØAttach the rear oscillating bracket as shown in fig.
  • Page 9 ® FU LL TAN K Sistemi Elettronici English English di Apertura Porte e Cancelli International registered trademark n. 804888 POSITIONING OF THE FRONT BRACKET Once the operator is attached to the post and the leaf set in the closed position execute the following operations: 1.
  • Page 10 ® FU LL TAN K Sistemi Elettronici English English di Apertura Porte e Cancelli International registered trademark n. 804888 INSTALLATION OF POSITIVE STOPS Ø Release the unit (as in fig. 24 of page 27) Ø Make the shaft come out for ¾ of its stroke Ø...
  • Page 11 ® FU LL TAN K Sistemi Elettronici English English di Apertura Porte e Cancelli International registered trademark n. 804888 TORQUE ADJUSTMENT (by pass valves) By-Pass Valves Grey Yellow Grey Yellow Fig. 22 Adjust the opening and closing forces of the gate so that the diagram of the force is respected (present in the regulation EN 12453);...
  • Page 12: Manual Release System

    Fig. 24 Fig. 25 WARNING: SEA recommends to the end user to release the operator only after having switched off the electric power. Always contact a professional installer in case of not correct working of the operator. PERI ODI CAL M AI N T EN AN CE...
  • Page 13 ® FU LL TAN K Sistemi Elettronici English English di Apertura Porte e Cancelli International registered trademark n. 804888 RISK EXAMINATION The points pointed by arrows in fig. 26 are potentially dangerous. The installer must take a thorough risk examination to prevent crushing, conveying, cutting, grappling, trapping so as to guarantee a safe installation for people, things and animals.
  • Page 14 SELF INSTALL - NEED TECHNICAL ASSISTANCE? OPTION 1: DIRECT WITH THE SERVICE DESK – QUICKEST AND MOST EFFECTIVE METHOD Submit your enquiry direct with the service desk at – service@automaticsolutions.com.au The service desk has the most experienced staff in Australia to help with your problem but they need your help. ...

This manual is also suitable for:

Full tank 200

Table of Contents