Technician Test Procedures; Programming The I850/I760 Unit; Connecting The Unit To The Rss Workstation - Motorola iDen i850 Field Service Manual

Digital multi-service, data-capable portable
Hide thumbs Also See for iDen i850:
Table of Contents

Advertisement

BASIC LEVEL TEST MODES AND PROCEDURES: Technician Test Procedures
31. Press Back to return to the Trace Mode display.
32. Scroll down to highlight Flags, and then press View to view the Flags display. This screen
displays the error log, which contains any errors logged by the unit software.
33. Press Back to return to the Trace Mode display.
34. Scroll down to highlight Coin Cell, and then press View to show the Preset Charging Voltage on
line 1 and Current Battery Voltage on line 2.
35. Press Back to return to the Trace Mode display.
36. Scroll down to highlight CE Status, and then press OK to view accessory type connected to the
unit.
37. Press Back to return to the Trace Mode display.
6.3

Technician Test Procedures

Technician Tests usually require special equipment to test the functionality of the components in the
unit.
The following tests check the software functionality of the unit:
Codeplug Help
Codeplug Troubleshooting
6.4

Programming the i850/i760 Unit

Use Radio Service Software (RSS) to activate a new software utility or to program specific codeplug
user information.
Refer to Radio Service Software's Help Menu, iDEN Service Bulletins, the Motorola iDEN website,
or contact iDEN Customer Care for information on the setup and use of RSS.
NOTE: iDEN Service Bulletins, Software Utilities, and Updates can be found online at:
http://idenphones.motorola.com/iden/support/
6.5

Connecting the Unit to the RSS Workstation

Some technician tests enter programming information into the unit. To perform these tests, the unit
must be correctly connected to the test equipment.
Recommended equipment: RS232 data cable(NKN6560A) or USB data cable(NKN6559A) and a
PC computer workstation with RSS installed.
NOTE: For a list of recommended programming equipment, applicable part numbers, and
descriptions, refer to Appendix A: Ordering Replacement Parts and Kits.
6-8
68P80400P94-O

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iden i760

Table of Contents