NOTE
When a high load electrical appliance is connected and in order to reduce voltage change, turn
the economy control switch to the "OFF"( ) position. This will allow the engine speed to
increase before the load is applied
In DC operation, turn the economy control switch to the "OFF"(
)position.
Connect both AC load and DC load, turn the economy control switch to the "OFF"(
) position.
"OFF" (
)
When the economy control switch turns to the "OFF" ( ) the engine runs at high speed.

3.3 Hour Meter

When the generator goes into overload protection mode, the overload indicator light (RED) will
come on, by pressing the "RESET" button the output of the generator can be recovered. It will be
unnecessary to restart engine.
Press and hold the "RESET" button for one second, until the overload indicator light (RED) goes off,
and the output indicator light (GREEN) comes on.
Under non-overload condition the "RESET" button does not have any function.
When the "DISP" button is pressed the backlight will come on. Successive presses of the "DISP"
button will display in turn at each press the Voltage - Frequency - Engine Speed & Cumulative Run
Time.
NOTE
If the "DISP" button is not pressed for more than 10 seconds the backlight will turn off.
RESET
DISP
BACKLIGHT
NOTE
When in protection condition, the output indicator light (GREEN) is off and the overload indicator
light (RED) is on.
When the generator is started the "RESET" function is available to recover from an overload
condition five times, after which time you will have to restart the engine.
PAGE 7