Technical Specifications - Hyundai HY1000Si User Manual

Petrol inverter generator
Hide thumbs Also See for HY1000Si:
Table of Contents

Advertisement

11.0

Technical Specifications

HY1000Si Technical Specifications
Specifications
Model
Type
Engine Displacement
Bore*Stroke
Compression Ratio
Rated Speed
Ignition System
Start System
Fuel Type
Oil Capacity
Oil Model
Model
Rated Frequency
Rated Voltage
Rated Current
Rated Speed
Rated Output Power
Max. Output Power
HY2000Si Technical Specifications
Specifications
Model
Type
Engine Displacement
Bore*Stroke
Compression Ratio
Rated Power
Ignition System
Start System
Fuel Type
Oil Capacity
Oil Model
Model
Rated Frequency
Rated Voltage
Rated Current
Rated Speed
Rated Output Power
Max. Output Power
Parameters
HS1200i.1
4-stroke, overhead valve,
single cylinder, forced-air cooling
3
53.2cm
43.5mm*35.8mm
1.8:5
-1
5500min
Recoil starter
Unleaded petrol
0.25L
SE 15W-30
HY 1000Si
50Hz
230V
3.9A
-1
5300min
0.9kVA
1.0kVA
Parameters
149F
4-stroke, overhead valve,
single cylinder, forced-air cooling
3
79cm
.
*
.
48
6mm
43
0mm
1.8:7
.
/
-1
2
3kVA
4500min
Full transistor
Recoil starter
Unleaded petrol
0.41L
SE 15W-30
HY 2000Si
50Hz
230V
7.0A
-1
4500min
1.6kVA
2.0kVA
PAGE 28
DC Output
Fuel Tank Volume
Continuous Running Time
Fuel Consumption
Working Ambient Temperature
Max. Altitude
﹡Noise (dB/4m) L
wA
﹡﹡ Noise (dB/7m) L
Dimensions (L*W*H )
Net Weight
Noise level is measured when the
turned to ''ON'' ( 
)
﹡ : L shows the guaranteed sound power tested
wA
by 2000/14/
.
EC
﹡ ﹡ : The noise level in "dB/7m" is the
arithmetic mean value of sound press level (L ) in
four directions measured 7 meters away from the
generator.
The noise level may vary in different environments.
DC Output
Fuel Tank Volume
Continuous Running Time
Fuel Consumption
Working Ambient Temperature
Max. Altitude
﹡Noise L
w A
﹡﹡ Noise L
p A
Dimensions (L*W*H )
Net Weight
Noise level is measured when the
)
turned to ''ON''(
﹡ : L
shows the guaranteed sound power tested
wA
by 2000/14/
.
EC
﹡ ﹡ : The noise level in "dB/7m" is the
arithmetic mean value of sound press level (L ) in
four directions measured 7 meters away from the
generator.
The noise level may vary in different environments.
12V/5A
2.2L
6.6
h
≤500g/(kW.h)
-20°C ~ 40°C
~40
12V/5A
1000m
90
54~59
pA
451mm * 242mm * 379mm
14kg
ECON Switch
is
pA
12V/5A
3.8L
8.0h
500g/(kW.h)
-20 ~40
1000m
90dB/4m
54~59dB/7m
510mm*455mm*280mm
20kg
is
ECON Switch
pA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hy2000si

Table of Contents