8.0

Maintenance.

The purpose of the maintenance schedule is to keep the generator in the best operating
condition.
WARNING
Stop the engine before performing any maintenance. If the engine must run, be sure the area is
well ventilated. The exhaust contains poisonous carbon monoxide gas.
Only use genuine Hyundai spares to replace worn components.
Maintenance Schedule.
Regular Service
Period (3)
Item
Engine
oil
Air
cleaner
Spark plug
Spark plug
Spark arrester
Valve clearance
Combustion
chamber
Fuel tank & filter
Fuel line
NOTE
(1) Service more frequently when used in dusty areas.
(2) These items should be serviced by your servicing dealer, unless you have the proper tools and
are mechanically proficient. Refer to dealer for service procedures.
(3) For commercial use and/or long hours of operation you must maintain proper maintenance
intervals.

8.1 Oil Change.

Drain the oil whilst the engine is still warm.
8.1.1 Loosen the maintenance cover screw, and remove the cover. 8.1.2
Remove the oil filler cap.
First
Each
month
or
use
10 hrs.
Check level
Change
Check
Clean
Check-adjust
Replace
Check-adjust
After every 300 hrs(2)
Clean
Every year(2)
Clean
Every 2 years (Replace if necessary)(2)
Check
PAGE 19
Every 3
Every 6
Every
2 years
months
months
or
or
or
50 hrs.
100 hrs.
300 hrs.
(1)
(2)