Yunca Gas LEEDZ Operations, Maintenance & Warranty Information page 19

Hide thumbs Also See for LEEDZ:
Table of Contents

Advertisement

supply to the pilot burner
11. When the brass nut is removed from the base of the pilot burner the pilot jet
will drop out. Insert new pilot jet from conversion kit ensuring the chamfered
end is facing upwards.
12. The gas can now be reconnected to the pilot and the burner module replaced
and reconnected.
13. When changing from N.G. to LPG, the in line restrictor, located in the rear
burner pipe where it attaches to the control, must me removed. When
changing from LPG to NG, this restrictor must be placed in rear burner pipe at
the control.
14. The brass reducer that couples the front burner pipe to the control must also
be changed and the reducer supplied with kit fitted.
15.
Test all connections for gas tightness and replace logs and door.
16. Update or replace appliance data plate for new specifications and gas type.
25-07-01
Page 19 of 22
Operation Instructions for Leedz Free Standing July 2001.doc

Hide quick links:

Advertisement

Table of Contents
loading