Clearances - Regency Fireplace Products Horizon HZ40E-NG10 Owners & Installation Manual

Hide thumbs Also See for Horizon HZ40E-NG10:
Table of Contents

Advertisement

installation
|
10

CLEARANCES

The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance
that this fireplace and vent system be installed only in accordance with these instructions.
Clearance:
A: Mantel Height (min.)
B: Sidewall (on one side)
C: Ceiling
(room and/or alcove)
D: Mantel Depth (max.)
E: Alcove Width
F: Alcove Depth
G: From Floor
Note:
D
A
G
F
Alcove
10 |
Regency Horizon ® HZ40E-10 Gas Fireplace
Dimension
17" (330mm)
Top of Fireplace Opening
8" (203mm)
Side of Fireplace Opening
22" (559mm)
Top of Fireplace Opening
13" (330mm)
22" Above Fireplace Opening
84" (2134mm)
Sidewall to Sidewall (Minimum)
36" (914mm)
Front to Back Wall (Maximum)
27" (686mm)
0"
F
B
E
Installed Close
to Floor
E
Measured From:
Top of Fireplace Opening
No hearth required
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
Flue Clearances to Combustibles
Horizontal - Top
Horiztonal - Side
Horiztonal - Bottom
Vertical
Passing through wall/
floor/ceiling - when
firestop is used.
The HeatWave Duct Kit and the Heat
Release Kit have different clearance
and framing requirements, check
the HeatWave and Heat Release
Heat Release Kit
manual for details.
Installed close
to ceiling.
Caution Requirements
WARNING
Fire hazard is an extreme risk
3"
2"
2"
2"
1-1/2"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Horizon hz40e-lp10Horizon hz40e series

Table of Contents