Minimum Clearances to Combustibles

The clearances listed below are minimum distances unless otherwise stated.
A major cause of fires is failure to maintain required clearances (airspace) to combustible materials. It is of the greatest importance that this decorative
gas appliance is installed only in accordance with these instructions.
B
Clearance
A: Sidewall
B: Ceiling
C: Min. Alcove Width
54" / 1372 mm
D: Max. Alcove Depth
A hearth is recommend but not required in front of this appliance. If bringing combustible flooring
up to the appliance it must be at the same level or lower than the appliance base. No combustible
material is permitted underneath the appliance.
• **For mantle clearances, see next page.
• (E): ***Measured from the inside edge of the faceplate/doors - reference only: 19-9/16'' (497 mm)
Dimension
8" / 203 mm
***From inside edge of faceplate / doors
60" / 1524 mm
From base of unit
From side wall to side wall
36" / 914 mm
From the front of the unit.
**
E***
C
Diagram 1
Measured From:
A
D
Gi25LE Gas Insert |
3

Advertisement

loading