Installation Checklist; Materials Required; Minimum Fireplace Dimensions; Clearances To Combustibles - Regency Fireplace Products Energy U31 Owners & Installation Manual

Hide thumbs Also See for Energy U31:
Table of Contents

Advertisement

installation
|
10
INSTALLATION
CHECKLIST
The Regency Gas Insert is installed as listed below.
1. Unit Location - check Clearances to Combus-
tibles.
2. Make the gas connections.
Convert to Propane Gas if necessary.
3. Install the flue or liner to the sliding draft hood.
4. Install Venting. Slide the unit into the fireplace.
Attach draft hood to the insert.
5. Test gas pressure.. Check aeration
6. Test for flue spillage.
7. Install the optional brick panels.
8. Install the log set.
9) Assemble and install the faceplate.
10) Install the glass front.
11) Install Safety Screen, Remote Control and
Optional Wall Thermostat.
12) Final check: Before leaving this unit with the
customer, the installer must ensure that the
appliance is firing correctly. This includes:
a)
Clocking the appliance to ensure the
correct firing rate.
b)
Adjusting the primary air, if required, to
ensure that the flame does not carbon.
c)
Ensuring that the appliance is venting
correctly.

MATERIALS REQUIRED

No electrical power supply is required for the gas
control to operate. A 120 Volt AC power cord is
hooked up to the fan. Plug the 3 wire cord into a
suitable receptacle. Do not cut the ground terminal
off under any circumstances. When connected
with 120 volts, the appliance must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with the current Canadian
Electrical Code CSA C22.1 (in Canada) or with
the current National Electrical Code ANSI/NFPA
70-1987 (in U.S.A.).
NOTE: This unit is equipped with a heat sensor
thermodisc which will prevent the blower
from operating until the unit reaches the
correct temperature.
10 |
Regency U31-10 Gas Fireplace Insert
MINIMUM FIREPLACE
DIMENSIONS
The minimum fireplace dimensions for the FPI gas
fireplace insert are shown in the following diagrams:
Standard
Faceplate
8-1/8
"
Low pro le
CLEARANCES TO
COMBUSTIBLES
From Unit
Sides
A 10" / 255 mm
Ceiling
B 47.5" / 1205 mm
Mantle
C See mantle
clearances
Max. Mantel Depth
G 12" / 305 mm
Min. Alcove Width
K 48" / 1220 mm
Max. Alcove Depth
L 36" / 915 mm
* No Hearth Required