The clearances listed below are Minimum distances unless otherwise stated:
A major cause of fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
decorative gas appliance be installed only in accordance with these instructions.
Clearance:
A: Sides
B: Ceiling
C: Mantel (Min. Height)*
D: Min. Hearth Depth
E: Min. Hearth Width
G: Max. Mantle Depth
K: Min. Alcove Width
L: Max. Alcove Depth
M: Optional mantel
defl ector
Notes: Non-combustible hearth required. If unit is raised 6" from the fl oor - no hearth is
required.
Otherwise:
Min. Hearth requirements - An R value of 1.75 is required to meet the requirements of the
hearth in front of this appliance. 1" of Calcium Silicate board available from Regency, part
number (296-936) plus 3/8" tile or equivalent would meet this requirement.
See part instruction sheet 919-133 for non-combustible Calcium Silicate board requirements.
MANTEL CLEARANCES WITHOUT DEFLECTOR
Allowable
Mantel Area
16" Min
From Top of
Door
Opening
Diagram 2
WARNING
Although this appliance passes safety
certifi cation, the hearth in front of the fi replace
becomes very hot when the fi replace heats. Do
not use the hearth as a seat or shelf.
12

MINIMUM CLEARANCES TO COMBUSTIBLES

Dimension
12" / 305 mm
From inside edge of faceplate / doors
60" / 1524 mm
Bottom of unit
*12" / 305mm
From top of unit, or 36" from bottom of unit
16"/ 406mm
From top of unit, or 40" from bottom of unit
14" / 356mm
44"/ 1016mm
12" / 305 mm
@ 48" (1219mm) from bottom of unit
56" / 1422 mm
36" / 914 mm
3-1/2" / 89mm
38
36
34
32
30
28
26
24
22
20
18
16
40"
From bottom
of unit
Measured From:
MANTEL CLEARANCES WITH 3-1/2" DEFLECTOR
Allowable
Mantel Area
12" Min
From Top of
Door
Opening
G
B
C
D
Diagram 1
36"
From bottom
of unit
Diagram 3
Note: A 3-1/2" mantel defl ector to reduce
mantel height to 36" from bottom of unit
@ 1"depth.
A noncombustible mantel may be
installed at a lower height if the framing
is made of metal studs covered with a
noncombustible board.