[BATTERY SETUP]

Conigure the settings for the battery to use.
Item
[BATTERY SELECT]
[EXT DC IN SELECT]
[BATT NEAR END CANCEL]
[BATT REMAIN FULL]
[BATTERY SETTING]
[BATTERY MODE]
[HYTRON140 NEAR
END]
[DIONIC HC NEAR END] Selects the near end voltage in steps of 0.1 V when [DIONIC HC] is selected in the main menu →
[ENDURA10 NEAR
END]
[PAG L96e NEAR END]
[TYPE A FULL]
[TYPE A NEAR END]
Chapter 6 Menu Operations — Menu list
Selects the battery to use.
[HYTRON140], [DIONIC HC], [ENDURA10], [PAG L96e]: Detects the battery charge level according to
the selected battery when the HYTRON140, DIONIC HC by Anton/Bauer, ENDURA10 (E-10) by IDX, or
PAG L96e by PAG battery is selected.
[TYPE A], [TYPE B], [TYPE C]: Select either item when a battery other than [HYTRON140], [DIONIC
HC], [ENDURA10], and [PAG L96e] is used. At this time, set [FULL] (full voltage), [NEAR END] (near end
warning voltage), or [END] (end voltage) in the main menu → [BATTERY SETUP] → [BATTERY SETTING]
(page 136) according to the battery in use.
[BATT STAT]: By selecting [BATT STAT] when using a battery whose charge level is detected as a
percentage value, near end and end operations are conducted according to the percentage value of the
charge level. Set the percentage value of [BATT STAT NEAR END] (near end) and [BATT STAT END]
(end) in the main menu → [BATTERY SETUP] → [BATTERY SETTING] (page 136) according to the
battery in use.
[ENDURA STAT]: Select it when ENDURA battery by IDX is used to perform near end and end operations
according to the percentage value of the charge level information. Set the percentage value of [ENDURA
STAT NEAR END] (near end) and [ENDURA STAT END] (end) in the main menu → [BATTERY SETUP] →
[BATTERY SETTING] (page 136) according to the battery in use.
f Factory setting: [DIONIC HC]
When the battery charge level percentage cannot be detected even if [BATT STAT] or [ENDURA STAT] is
set, it will follow the setting value of [TYPE A]. Make sure that the [TYPE A] setting values for [FULL] (fully
charged), [NEAR END] (near end), and [END] (end) are appropriate for the battery in use.
Sets the type of charge level detection when a battery is connected to the <DC IN> terminal. Also detects a
charge level that corresponds to the selected type.
Selection of a battery type is the same as that of [BATTERY SELECT].
Displays the analog voltage in the viewinder.
[DC PWR SUPPLY], [HYTRON140], [DIONIC HC], [ENDURA10], [PAG L96e], [TYPE A], [TYPE B],
[TYPE C]
f Factory setting: [DC PWR SUPPLY]
If set to [ON], the warning sound and warning display output can be canceled when the <DISP/MODE
CHK> switch is pushed towards the <CHK> side at battery near end.
[ON], [OFF]
f Factory setting: [ON]
Sets the content of the battery remaining charge bar of SmartUI when a battery with charge level display
function is used.
[70%]: Displays as full at 70%.
[100%]: Displays as full at 100%.
f Factory setting: [70%]
Selects whether to set the near end voltage of a battery.
[AUTO]: Automatically set.
[MANUAL]: Manually set.
f Factory setting: [AUTO]
Selects the near end voltage in steps of 0.1 V when [HYTRON140] is selected in the main menu →
[BATTERY SETUP] → [BATTERY SELECT].
This item is enabled when [BATTERY MODE] is set to [MANUAL].
[12.0V]...[15.0V]
f Factory setting: [13.1V]
[BATTERY SETUP] → [BATTERY SELECT].
This item is enabled when [BATTERY MODE] is set to [MANUAL].
[12.0V]...[15.0V]
f Factory setting: [13.1V]
Selects the near end voltage in steps of 0.1 V when [ENDURA10] is selected in the main menu →
[BATTERY SETUP] → [BATTERY SELECT].
This item is enabled when [BATTERY MODE] is set to [MANUAL].
[12.0V]...[15.0V]
f Factory setting: [13.1V]
Selects the near end voltage in steps of 0.1 V when [PAG L96e] is selected in the main menu →
[BATTERY SETUP] → [BATTERY SELECT].
This item is enabled when [BATTERY MODE] is set to [MANUAL].
[12.0V]...[15.0V]
f Factory setting: [13.1V]
Selects the voltage for full display in steps of 0.1 V when [TYPE A] is selected in the main menu →
[BATTERY SETUP] → [BATTERY SELECT].
The [TYPE A] factory setting corresponds to the IDX ENDURA ELETE.
[13.0V]...[17.0V]
f Factory setting: [15.6V]
Selects the near end voltage in steps of 0.1 V when [TYPE A] is selected in the main menu → [BATTERY
SETUP] → [BATTERY SELECT].
The [TYPE A] factory setting corresponds to the IDX ENDURA ELETE.
[11.0V]...[15.0V]
f Factory setting: [13.2V]