Removing A Hot-Plug Fan Blank Or Module If The Server Is Installed In A Ball-Bearing Rail System With The Cable Management Arm - HP ProLiant DL380e Gen8 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL380e Gen8:
Table of Contents

Advertisement

Two processor, redundant
In a redundant fan mode:
If one fan fails, the system continues to operate without redundancy. This condition is indicated by
o
a flashing amber Health LED.
If two fans fail, the system shuts down.
o
The minimum fan requirement to make this server bootable is four fans in bays 2, 4, 5, and 6.
Removing a hot-plug fan blank or module if the server is installed
in a ball-bearing rail system with the cable management arm
CAUTION:
functioning server has all feature bays populated with the required component or blank and the
access panel is installed within 60 seconds of being serviced.
To remove the component:
Pull down the quick release levers on each side of the server.
1.
WARNING:
adequately stabilized before extending a component from the rack.
Extend the server on the rack rails until the server rail-release latches engage.
2.
If the server does not extend from the rack, use a T-25 Torx screwdriver to loosen the screws located
within the lever housing.
Open the latch, slide the access panel to the rear of the chassis, and then remove the access panel.
3.
If the latch is locked, use a T-15 Torx screwdriver to unlock the latch.
Do one of the following:
4.
Remove the fan blank.
o
Fan
Fan
To prevent the potential for thermal damage and system shutdown, ensure that a
To reduce the risk of personal injury or equipment damage, be sure that the rack is
Fan
Fan
Removal and replacement procedures 45
Fan
Fan