Fbwc Module Led Definitions - HP ProLiant DL380e Gen8 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL380e Gen8:
Table of Contents

Advertisement

Item
LED
Do not remove
3
Drive status
4
IMPORTANT:
installed in the server, the embedded Smart Array B120i Controller is disabled automatically.
When this condition occurs:
Drives connected to the system board operate in AHCI or Legacy mode.
In AHCI or Legacy mode, drives cannot be a part of a hardware RAID or a logical drive.
The Locate, Drive status, and Do not remove LEDs of the affected drives are disabled.

FBWC module LED definitions

The FBWC module has three single-color LEDs (one amber and two green). The LEDs on the cache module
installed on a storage controller are duplicated on the reverse side of the module to facilitate status viewing.
Cache module installed on a storage controller
Status
Definition
Solid white
Do not remove the drive. Removing the drive causes one or more of
the logical drives to fail.
Off
Removing the drive does not cause a logical drive to fail.
Solid green
The drive is a member of one or more logical drives.
Flashing green
The drive is rebuilding or performing a RAID migration, stripe size
migration, capacity expansion, or logical drive extension, or is
erasing.
Flashing
The drive is a member of one or more logical drives and predicts
amber/green
the drive will fail.
Flashing amber
The drive is not configured and predicts the drive will fail.
Solid amber
The drive has failed.
Off
The drive is not configured by a RAID controller.
When the SAS-enabled riser board with the Smart Array B320i Controller is
Component identification 96