8 Monitoring cluster operations
Monitoring the system status
The storage monitoring function gathers system status information and generates a monitoring
report. The GUI displays status information on the dashboard. This section describes how to the
use the CLI to view this information.
Monitoring intervals
The default monitoring interval is 15 minutes (900 seconds). You can change the interval setting
by using the following command to change the <interval_in_seconds> variable:
ibrix_host_tune -C
vendorStorageHardwareMonitoringReportInterval=<interval_in_seconds>
NOTE:
The storage monitor will not run if the interval is set to less than 10 minutes.
Viewing storage monitoring output
Use the following command to view the status of the system:
ibrix_vs -i -n <storagename>
To obtain the storage name, run the ibrix_vs -l command. For example:
# ibrix_vs -l
NAME
TYPE
-----
----
x303s
exds
Monitoring X9720/X9730 hardware
The GUI displays status, firmware versions, and device information for the servers, chassis, and
system storage included in X9720 and X9730 systems.
Monitoring servers and chassis
Select Hardware from the Navigator to view information about the servers and chassis included
in your system. The Servers panel lists the servers included in each chassis. The Blade Server panel
provides additional information for the selected server.
58
Monitoring cluster operations
IP
PROXYIP
----------
-------
172.16.1.1