HP IBRIX X9720 System Administrator Manual page 115

Hide thumbs Also See for IBRIX X9720:
Table of Contents

Advertisement

Use kill -9 to kill any likewise services that are still running.
4.
From the management console, unmount all X9000 file systems:
<ibrixhome>/bin/ibrix_umount -f <fsname>
Upgrading the management console
Complete the following steps on the management console:
1.
Force a backup of the configuration:
<ibrixhome>/bin/ibrix_fm -B
The output is stored at /usr/local/ibrix/tmp/fmbackup.zip. Be sure to save this file
in a location outside of the cluster.
2.
Move the <installer_dir>/ibrix directory used in the previous release installation to
ibrix.old. For example, if you expanded the tarball in /root during the previous X9000
installation on this node, the installer is in /root/ibrix.
3.
Expand the distribution tarball or mount the distribution DVD in a directory of your choice.
Expanding the tarball creates a subdirectory named ibrix that contains the installer program.
For example, if you expand the tarball in /root, the installer is in /root/ibrix.
4.
Change to the installer directory if necessary and execute the following command:
./ibrixupgrade -f
5.
Verify that the management console started successfully:
/etc/init.d/ibrix_fusionmanager status
The status command confirms whether the correct services are running. Output is similar to
the following:
Fusion Manager Daemon (pid 18748) running...
6.
Check /usr/local/ibrix/log/fusionserver.log for errors.
Upgrading the file serving nodes
After the management console has been upgraded, complete the following steps on each file
serving node:
1.
Move the <installer_dir>/ibrix directory used in the previous release installation to
ibrix.old. For example, if you expanded the tarball in /root during the previous X9000
installation on this node, the installer is in /root/ibrix.
2.
Expand the distribution tarball or mount the distribution DVD in a directory of your choice.
Expanding the tarball creates a subdirectory named ibrix that contains the installer program.
For example, if you expand the tarball in /root, the installer is in /root/ibrix.
3.
Change to the installer directory if necessary and execute the following command:
./ibrixupgrade -f
The upgrade automatically stops services and restarts them when the process completes.
4.
When the upgrade is complete, verify that the X9000 Software services are running on the
node:
/etc/init.d/ibrix_server status
The output should be similar to the following example. If the IAD service is not running on your
system, contact HP Support.
IBRIX Filesystem Drivers loaded
ibrcud is running.. pid 23325
IBRIX IAD Server (pid 23368) running...
5.
Execute the following commands to verify that the ibrix and ipfs services are running:
lsmod|grep ibrix
Manual upgrades
1 15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ibrix x9730

Table of Contents