Completing The Restore - HP IBRIX X9720 System Administrator Manual

Hide thumbs Also See for IBRIX X9720:
Table of Contents

Advertisement

1 1. The wizard now registers a passive Management Console (Fusion Manager) on the blade
and then configures and starts it.
The wizard then runs additional setup scripts.
NOTE:
connection when the platform scripts are executed. After a short period of time you can again
connect to the iLO and bring up the virtual console.
When the configuration is complete, a message reporting the location of the log files appears:
Logs are available at /usr/local/ibrix/autocfg/logs.
X9730 configuration logs are available at /var/log/hp/platform/install/
x9730_install.log.

Completing the restore

1.
Ensure that you have root access to the node. The restore process sets the root password to
hpinvent, the factory default.
2.
Verify information about the node you restored:
On X9730 systems, run the following command, specifying the hostname of the node:
ibrix_chassis -i -s -h <hostname>
The command reports status, firmware versions, locations, and other information for the
server, CPUs, memory DIMMs, iLO modules, NICs, temperature sensors, storage
controllers, drives, and volumes.
On X9720 systems, run the exds_stdiag command from the node that was just restored.
You should be able to see the shared storage, just as you can from the other server blades
in the chassis.
3.
Review vendor storage information. Run the following command from the node hosting the
active Fusion Manager:
ibrix_vs -i
The command reports status, UUIDs, firmware versions, and other information for servers,
storage components, drive enclosures and components, volumes, and drives. It also shows
the LUN mapping.
If you are connected to iLO and using the virtual console, you will lose the iLO
Completing the restore 165