PCNTNW-NW-074 The hardware interrupt cannot be set.
Explanation: An attempt was made to initialize a given hardware interrupt. The
attempt was not successful.
Action: Verify that the Ethernet controller is enabled. If the Ethernet controller is
enabled, go to "Starting the diagnostic programs" on page 135 to run the diagnostic
programs.
If you have an Ethernet adapter installed, make sure that the adapter does not share
an IRQ with any other device.
PCNTNW-NW-075 The Multiple Link Interface Driver (MLID) cannot be registered with the Link
Support Layer (LSL).
Explanation: An error occurred while the driver was trying to register with the LSL.
Action: Check the version of the NetWare or IntraNetWare Operating System. Make
sure that this driver is correct for the version of NetWare or IntraNetWare that you
are using. Restart the server.
PCNTNW-NW-079 The Multiple Link Interface Driver (MLID) did not initialize MSMTx Free Count.
Explanation: The MSMTx Free Count is not initialized correctly.
Action: Restart the server. If the problem persists, call for service.
PCNTNW-NW-086 The driver parameter block is too small.
Explanation: The driver parameter block is too small.
Action: Restart the server. If the problem persists, call for service.
PCNTNW-NW-087 The media parameter block is too small.
Explanation: The driver media parameter block is too small.
Action: Restart the server. If the problem persists, call for service.
PCNTNW-NW-091 The hardware configuration conflicts.
Explanation: You tried to load a new frame type for the existing controller. The
hardware assumptions made in doing so are incorrect. This error can also occur if
you try to specify a mode (such as, redundancy) that conflicts with another specified
mode.
Action: Make sure that your hardware configuration matches the software settings.
PCNTNW-NW-126 The group bit in the node address override was cleared.
Explanation: The IEEE address has a group bit that indicates that an address belongs
to a group of stations. This bit is used only as a destination address; it cannot be used
as a source address. You tried to enter a source address with this bit set. The driver
cleared the group bit of the source address.
Action: None necessary, message is for information only.
PCNTNW-NW-127 The local bit in the node address override was set.
Explanation: The local bit in the IEEE address format indicates that the addresses are
being managed locally. If you use the node address override capabilities of this
driver to enter a new address, the local bit must be set. You entered an address
without the local bit set. The driver has set the local bit.
Action: None necessary, message is for information only.
Table 23. Novell NetWare or IntraNetWare ODI driver messages for the Ethernet
controller
Chapter 7. Solving problems
163