IBM Netfinity 6000R User Reference Manual page 144

Hide thumbs Also See for Netfinity 6000R:
Table of Contents

Advertisement

POST message
00180100
A PCI adapter has requested memory resources that are not available.
Action:
00180200
A PCI adapter has requested an I/O address that is not available, or the PCI adapter
might be defective.
Action:
00180300
A PCI adapter has requested a memory address that is not available, or the PCI adapter
might be defective.
Action:
00180400
A PCI adapter has requested a memory address that is not available.
Action:
00180500
A PCI adapter ROM error occurred.
Action:
If you cannot isolate and correct the problem, call for service.
00180600
A PCI-to-PCI bridge error occurred. More than one PCI bus tried to access memory
below 1 MB.
Action:
If you cannot isolate and correct the problem, call for service.
00180700
xxxxyyyy
is the PCI device ID.)
Action:
00180800
An unsupported PCI device is installed.
Action:
If the problem persists, call for service.
Table 18. POST error messages
130
IBM® Netfinity® 6000R User's Reference
1. Make sure that the PCI adapter and all other adapters are set correctly
in the Configuration/Setup Utility program. If the memory resource
settings are not correct, change the settings.
2. If all memory resources are being used, you might need to remove an
adapter to make memory available to the PCI adapter. Disabling the
adapter BIOS on the adapter might correct the error. Refer to the
documentation provided with the adapter.
1. Make sure that the I/O address for the PCI adapter and all other
adapters are set correctly in the Configuration/Setup Utility program.
2. If the I/O port resource settings are correct, the PCI adapter might be
defective. Call for service.
1. Make sure that the memory address for all other adapters are set
correctly in the Configuration/Setup Utility program. If the memory
resource settings are not correct, change the settings.
2. If the memory resource settings are correct, the PCI adapter might be
defective. Call for service.
If all memory addresses are being used, you might need to remove an
adapter to make memory address space available to the PCI adapter.
Disabling the adapter BIOS on the adapter might correct the error. Refer to
the documentation provided with the adapter.
Remove the PCI adapters. If you can start the server without the adapters,
reinstall each adapter one at a time and retest after each is reinstalled.
When an adapter fails, replace it.
Remove the PCI adapter that has the PCI bridge. If you can start the server
without the adapter, reinstall and retest the adapter. If the adapter fails,
replace it.
Planar PCI device does not respond. (Where
Call for service.
Remove the PCI adapters. If you can start the server without the adapters,
reinstall each adapter one at a time and retest after each is reinstalled.
When an adapter fails, replace it.
Description
is the PCI vendor ID and
xxxx
yyyy

Advertisement

Table of Contents
loading

Table of Contents