Relay; Energy-Manager(In Relay Menu Item) - Fronius Primo 3.0-1 Operating Instructions Manual

Grid-connected inverter
Hide thumbs Also See for Primo 3.0-1:
Table of Contents

Advertisement

Available languages

Available languages

IMPORTANT! In order for the logging function to work correctly the time must be set cor-
rectly.

Relay

Activate relay, relay settings, relay test
Setting range
* these are only shown if the 'E-Manager' function has been activated under 'Relay mode'.
Relay mode
for selecting the different functions of the floating switch contact in the data communication
area:
-
-
-
Setting range
Factory setting
Relay test
Function test to determine whether the floating switch contact switches
Switch-on point (only if 'Energy-Manager' function is activated)
for setting the effective power limit beyond which the floating switch contact is switched on
Factory setting
Setting range
Switch-off point (only if 'Energy-Manager' function is activated)
for setting the effective power limit beyond which the floating switch contact is switched off
Factory setting
Setting range
30
Relay mode / Relay test / Switch-on point* / Switch-off point*
Alarm function
Active output
Energy-Manager
ALL / Permanent / OFF / ON / E-Manager
ALL
Alarm function:
Permanent /
Switch the floating switch contact for permanent and temporary ser-
ALL:
vice codes (e.g. brief interruption to energy being fed into the grid, a
service code occurs a certain number of times a day - can be adjusted
in 'BASIC' menu)
Active output:
ON:
The floating NO contact is on all the time the inverter is in operation
(as long as the display is not dark and is displaying something).
OFF:
The floating NO contact is off.
Energy-Manager:
E-Manager:
Further details on the 'Energy-Manager' function may be found in the
"Energy-Manager" section.
1000 W
Switch-off point - max. nominal output of inverter / W / kW
500
0 - Switch-on point / W / kW