The Basic menu

General

The Basic menu is used to set the following parameters, which are important for installing
and operating the inverter:
-
-
-
-
-
Access the Basic
menu
DC operating mode
Fixed voltage
MPPT1 / MPPT2 start voltage
USB logbook
Event counter
A c c e s s C o d e
The Basic menu appears.
Use the 'Up' or 'Down' keys to select the desired menu item
7
Press the 'Enter' key to open the desired menu item
8
Press the 'Esc' key to exit the Basic menu
9
-
Grounding mode / grounding monitor-
ing
-
Insulation settings
-
TOTAL reset
Press the "Menu" key
1
The menu level appears.
Press the unassigned 'Menu / Esc'
2
key
5 times
'Access Code' is displayed in the 'CODE'
menu; the first digit starts flashing.
Enter the code 22742: Use the 'Up'
3
and 'Down' keys to select a value for
the first digit of the code
Press 'Enter'
4
The second digit flashes.
Repeat steps 3 and 4 for the second,
5
third, fourth and fifth digit of the ac-
cess code until...
the selected code starts flashing.
Press 'Enter'
6