Relay (Floating Contact Switch) - Fronius Primo 3.0-1 Operating Instructions Manual

Hide thumbs Also See for Primo 3.0-1:
Table of Contents

Advertisement

Available languages

Available languages

Logging interval
Activate / deactivate the USB logging function and specify a logging interval
Unit
Setting range
Factory setting
30 min.
20 min.
15 min.
10 min.
5 min.
No log
IMPORTANT! In order for the USB logging function to work correctly the time
must be set correctly. Setting the time is discussed in the section "Menu items in
the Setup menu" - "Clock".
Relay (floating
Status codes (state codes), the status of the inverter (e.g. feeding energy into the
contact switch)
grid) or Energy Manager functions can be displayed using the floating switch con-
tact (relay).
Setting range
* these are only shown if the "E-Manager" function has been activated under "Re-
lay mode".
Relay mode
The following functions can be shown using relay mode:
-
-
-
Setting range
Factory setting
32
Minutes
30 min. / 20 min./ 15 min./ 10 min./ 5 min./ No log
30 min.
The logging interval is 30 minutes; every 30 minutes new
logging data will be saved to the USB flash drive.
The logging interval is 5 minutes; every 5 minutes new
logging data will be saved to the USB flash drive.
No data is saved
Relay mode / Relay test / Switch-on point* / Switch-off
point*
Alarm function (Permanent / ALL / GAF)
Active output (ON / OFF)
Energy Manager (E-Manager)
ALL / Permanent / GAF / OFF / ON / E-Manager
ALL
Alarm function:
ALL / Per-
Switching the floating switch contact for permanent and tem-
manent:
porary service codes (e.g. brief interruption to energy being
fed into the grid, a service code occurs a certain number of
times a day - can be adjusted in the "BASIC" menu)

Advertisement

Table of Contents
loading

Table of Contents