Toshiba e-studio 167 Service Manual page 119

Hide thumbs Also See for e-studio 167:
Table of Contents

Advertisement

(3)
Take off the CIS unit drive belt-1.
Note:
When assembling the CIS unit drive belt-1,
assemble it while the fixing screw is loos-
ened. Then tighten the fixing screw of the
tension bracket.
[J]
CIS unit drive belt-2
(1)
Take off the scanner top cover.
P.6-18 "[B] Scanner top cover"
(2)
Take off the right rear cover.
P.2-22 "[I] Right rear cover"
(3)
Take off the CIS unit drive belt-1.
P.6-26 "[I] CIS unit drive belt-1"
(4)
Loosen 2 fixing screws of the scan motor.
(5)
Take off the CIS unit drive belt-2.
Note:
When assembling the CIS unit drive belt-2,
be sure to perform the tension adjustment for
the scan motor.
P.6-20 "[D] Scan motor (M1)"
© 2007 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Fig. 6-38
Fig. 6-39
CIS unit drive belt-2
Fig. 6-40
6 - 27
Scan motor