Troubleshooting
4.1

No display on InfoWIN

Code Meaning/effect
No display
Boiler is off, cannot be switched on with
the ON/OFF button.
4.2

Information messages

Code Meaning/effect
Replenish fuel
IN 581
The reserve supply container is almost
empty. Top up pellets.
Reserve supply container empty
IN 582
The reserve supply container is empty.
Top up pellets. Burner is locked.
Clean boiler and burner
IN 590
Perform cleaning and confirm in opera-
tor level.
Door open
IN 595
Burner locked. Only open the door
when the burner is switched off.
Cause/remedy
a) No electricity, check the cable to the device and the building fuse.
b) No electricity, device fuse defective – check and replace if necessary – see
page 55, Fig. 163.
c) InfoWIN plug loose or poorly connected together if connected at all during
installation – check and connect together firmly if necessary, plug is loca-
ted on the side at the top behind the right side panel cladding – see instal-
lation instructions; Installing the cladding.
Cause/remedy
Boiler continues to heat until the remaining fuel quantity has been consumed.
a) FireWIN Klassik (without feed):
Fill fuel into the fuel container (see section 2.3).
b) FireWIN Premium/Exklusiv (with feed): Feed is switched off in „feed ope-
rating mode" (see section 2.8.1.2). In „Feed operating mode" menu item,
set to „with enable time" , „with start time" or „without time control" .
The reserve supply container is empty.
a) FireWIN Klassik without feed:
Fill fuel into the fuel container (see section 2.3).
b) FireWIN Premium/Exklusiv (with feed):
Feed is switched off in „feed operating mode" (see section 2.8.1.3). In „Feed
operating mode" menu item, set to „with enable time" , „with start time"
or „without time control" .
Boiler and burner are still operating.
Boiler and burner must be cleaned or the both ash pan(s) (see Fig. 162) emp-
tied (see sections 3.4, 3.5 and 3.6). Following cleaning, confirm cleaning on
the InfoWIN operator level (see section 2.8.1.1).
Cladding door is open, burner locked.
a) Close the cladding door.
b) Door switch on cladding door does not switch correctly, adjust – see instal-
lation instructions.