Heating System Operation; Firewin With Mes System Control - Baxi Bioflo 12 kW Granite User Operating Instructions Manual

Pellet central heating system boiler
Table of Contents

Advertisement

Operation
2.9

Heating system operation

2.9.1 FireWIN with MES system control

Switching on – Automatic operation:
1. Press the ON/OFF button
up green and a self-test is performed (see also section 2.5.2). After a successful self-test and if a setpoint is
transferred by the system control, the FireWIN automatically starts operation.
2. Set the operating mode switch(es) on the MES control module(s) to „Automatic operation"
is operated (temperatures and operating times set) using the user module (installed in the living area) – ple-
ase refer to the MES and user module instructions.
ON/OFF button
Fig. 120
FireWIN with MES system control
For operation of the MES and user module(s), please see the respective operating instructions.
Switching off:
1. Set the operating mode to „Standby"
2. If the boiler has been out of service for an extended period during the summer months, press the ON/OFF button
on the InfoWIN unit.
The anti-freeze function is not active when the boiler is shut off.
Flue cleaning function:
This is operated using the InfoWIN unit – see section 2.5.6.
Emergency operation:
In the event that the control system fails, selecting the „Manual operation" mode on the MES control module
and InfoWIN unit
on the InfoWIN panel, the display lighting is switched on, the signal lamp lights
InfoWIN operating unit
using the user module (installed in the living area).
(see section 2.5.5) will activate emergency operation to maintain heat and hot water .
Operating mode switch
38
. The system

Advertisement

Table of Contents
loading