3.4

Changing P4 setting: Eco or comfort mode

Fig.5
Eco or comfort mode
R
3x
LT.NL.W6H.000.073
3.5

Changing P6 setting: display on/off

Fig.6
Display on/off
R
5x
LT.NL.W6H.000.075
7604454 - v.04 - 22072014
Note - No hot water
Beware; the system boiler in combination with an external calorifier
will not warm up the calorifier in the Eco-mode. So, if the calorifier
is empty, the tap water will be cold.
0 = Comfort mode
1 = Eco mode
2 = regulated by controller (= factory setting)
Change the mode as follows:
Press [Enter]-key until codes pK and K1 are displayed alternately.
Press [+]-key 3x until codes pK and K4 are displayed alternately.
Press [Enter]-key; setting of 'eco or heat retention' mode is displayed
(mode 2 = heat retention and regulator-dependent, factory setting).
Press [-]-key to change this mode, for example mode 1 (=eco mode).
Press [Enter]-key to confirm this mode; codes pK and K4 are
displayed alternately.
Press [Reset]-key to switch boiler to operating mode.
Change the display setting as follows:
Press [Enter]-key until codes pK and K1 are displayed alternately.
Press [+]-key 5x until codes pK and K6 are displayed alternately.
Press [Enter]-key; you will see mode 2 (= 'Display automatically off',
factory setting).
Press [-]-key to change this mode to mode 1 (= 'Display remains on').
Press [Enter]-key to confirm this mode; codes pK and K6 are
displayed alternately.
Press [Reset]-key to switch boiler to operating mode.