Electrolux EIGD55H Technical & Service Manual page 55

Wave-touch & iq-touch front-load dryer
Hide thumbs Also See for EIGD55H:
Table of Contents

Advertisement

Error
Fault
Code
Outlet Control
Outlet Control Thermistor or wir-
E72
Thermistor short
ing defective.
circuit
Inlet Control Thermistor or wiring
Inlet Control
E73
Thermistor open
defective.
circuit.
Motor Relay failure
Motor Relay stuck open or
E74
closed; Wiring defective.
Communication
Wiring, Electronic Control Board,
E91
or Interface Board defective
Error
Electronic Control Board incom-
Incompatible
E92
patible with Interface Board
protocol
Wrong configuration data loaded,
Machine configu-
E93
Interface Board or Electronic
ration checksum
Control Board or wiring defective.
error
Wrong configuration data loaded
Cycle configuration
E94
or Electronic Control Board defec-
checksum error.
tive
Wrong configuration data loaded,
E97
Program mismatch
Electronic Control Board
defective
Line frequency out of limits or
Main Supply
EA1
Electronic Control Board faulty.
Frequency out of
Range
Line voltage too high or Electronic
Voltage too high
EA2
Control Board faulty.
Line voltage too low or Electronic
Voltage too low
EA3
Control Board faulty.
Line connections in home faulty,
EA4
Improper home
wiring or Electronic Control Board
wiring
defective.
Electronic Control Board
Main V Sensing
EA5
defective
failure
High vent restriction, Exhaust
EF1
Vent Blocked
Control Thermistor, Inlet Control
Thermistor, or Electronic Control
Board defective.
Exhaust blocked; Exhaust Control
Max Timeout Timer
EF3
Thermistor, Inlet Control
Thermistor, Contact Sensor or
Electronic Control Board
defective.
Console button or Interface Board
Key Stuck
EF8
defective
Possible Fault Conditions
Possible Solutions
Check resistance of Outlet Control Thermistor, and check wiring for
short circuit across Thermistor connections. Resistance should be
between 4.9K Ohm and 6.2K Ohm at room temperature (68-77° F or
20-25° C). Replace Outlet Control Thermistor and/or wiring and retest.
Check resistance of Inlet Control Thermistor, and check wiring for
open circuit. Resistance should be between 47K Ohm and 66K Ohm
at room temperature (68-77° F or 20-25° C). Replace Inlet Control
Thermistor and/or wiring and retest.
If motor runs continuously with power applied check for short circuit
across motor relay (RL2), or L1 applied to motor relay output (J3-1)
with cycle stopped. If motor does not start when "start" key is pressed,
check for open circuit between L1 and motor relay connection (J3-2). If
no wiring problems found, replace Electronic Control Board.
Check connections between Electronic Control Board and Interface
Board. If no wiring problems, replace Electronic Control Board or
Interface Board.
Check if correct Interface Board console and Electronic Control Board
are installed. Replace appropriate hardware.
Check if correct Interface Board and console are installed. Replace
Interface Board and/or console.
Replace Electronic Control Board.
Replace Electronic Control Board.
Check frequency of line voltage.
Check amplitude of line voltage.
Check amplitude of line voltage.
Check wiring at terminal block for L1-N-L2 wired incorrectly.
Replace Electronic Control Board.
Check vent restrictions and resistance values of Exhaust Control
Thermistor and Inlet Control Thermistor.
Check vent restriction, Contact Sensor, and resistance values of
Exhaust Control Thermistor and Inlet Control Thermistor.
Check buttons for activation when pressed. Replace console or
Interface Board as appropriate
3-21