Electrical Connection (Non-Canada) 4 Wire Cord - Electrolux EIGD55H Technical & Service Manual

Wave-touch & iq-touch front-load dryer
Hide thumbs Also See for EIGD55H:
Table of Contents

Advertisement

Installation Information
Electrical Connection
(non-Canada) - 4 Wire Cord
ELECTRICAL SHOCK HAZARD
FAILURE TO DISCONNECT POWER SOURCE
BEFORE SERVICING COULD RESULT IN
PERSONAL INJURY OR EVEN DEATH.
1. Turn off power supply to outlet.
2. Remove the screw securing the terminal block
access cover in the lower corner on the back of the
dryer.
3. Install a UL-approved strain relief according to the
power cord/strain relief manufacturer's instructions in
the power cord entry hole below the access panel. At
this time, the strain relief should be loosely in place.
4. Thread an UNPLUGGED, UL-approved, 30 amp.
power cord, NEMA 14-30 type ST or SRDT, through
the strain relief. (See Figure 2-10)
5. Disconnect the internal (BLACK) dryer harness
ground wire from the (GREEN) ground screw next to
the terminal block. (See Figure 2-11)
2
6. Attach the ground (GREEN) power cord wire to the
cabinet with the ground (GREEN) screw. Tighten
the screw securely.
7. Move the internal dryer harness ground
(BLACK) wire to the terminal block and attach
it along with the neutral (WHITE) power cord
wire conductor to the center, SILVER colored
terminal on the terminal block. Tighten the
screw securely.
8. Attach the RED and BLACK power cord
conductors to the outer, BRASS colored
terminals on the terminal block. Tighten both
screws securely.
ELECTRICAL SHOCK HAZARD
DO NOT MAKE A SHARP BEND OR CRIMP
WIRING/ CONDUCTOR AT CONNECTIONS.
9. Follow manufacturer's guidelines for firmly
securing the strain relief and power cord.
10. Reinstall the terminal block cover..
30 Amp
NEMA 14-30
If a terminal screw falls during cord installation,
it can be retrieved in the terminal screw recovery
slot below the access panel.
Move internal ground (Black)
wire to neutral (Silver)
terminal for 4-wire system
Green
ground screw
Green
ground wire
Black or Red
power wire
2-10
Neutral
Ground
White wire
Green
wire
Access Cover
Screw
Terminal
Block
Line 2
Brass Terminal
Neutral
Silver Terminal
Line 1
Brass Terminal
Internal Ground
Green Screw
Install
UL-approved
strain relief here
Terminal Screw
Recovery Slot
Figure 2-10.
Neutral terminal
Neutral
White wire
Black or Red
power wire
Figure 2-11.