Appendix Aproblem Solving Guide - AVE RegCom-Pro Operation Manual

Pos / cash register interface
Table of Contents

Advertisement

APPENDIX A
NO DATA ON-SCREEN and/or REGISTER LED NOT FLASHING
1. Press the "Reset" button on the RegCom-Pro front panel.
2. Incorrect register selected in the REGISTER SELECT menu.
3. Data cable is miswired.
4. Data cable is too long or did not use shielded cable.
5. May be connected to the wrong port.
6. Need RS-232 Optical Isolation so enable this feature in the RegCom-Pro
REGISTER LED FLASHING but NO or Wrong DATA ON-SCREEN
1. Incorrect register selected in the REGISTER SELECT menu.
2. Baud Rate wrong, change to Auto Baud rate and do transaction
3. Interface Type set wrong
3. Data cable is miswired.
4. Data cable is too long or did not use shielded cable.
5. May be connected to the wrong port.
PROBLEMS WITH ECR / TPIF BOARDS
1. Upon regsiter power up verify on-screen ECR power up test.
2.Check that the board is seated properly in the register.
3. Check jumper settings on the board if applicable.
4. For ECR boards make sure the 2 pin data cable is plugged in correctly.
PROBLEMS WITH N2RS, NCR2RS, DTS2RS, B2RS ETC.
1. Check the cable to the register.
2. If RegCom-Pro was working and stopped, power cycle the system. Turn off the register, unplug the power to the
N2RS, and unplug the power to the VSI-Pro. Now power up the system, plug in the VSI-Pro and the N2RS. Turn
on the register and do a transaction. The data should re-appear.
3. Check the cable between the RegCom-Pro and the N2RS.
RegCom-Pro POS / Cash Register Interface
66
PROBLEM SOLVING GUIDE