SYNTIA
5.2.

Error codes

ERROR
CODES
01
03
04
05
10
11
14
15
19
Saeco International Group
The grinder is blocked (burrs jammed or sensor not reading properly)
The brewing unit is blocked in work position (microswitch not released
in up position after 3", torque error trying to move down, descent time
out exceeded)
The brewing unit is blocked in home position (microswitch not released
in down position after 3", torque error trying to move up, ascent time
out exceeded)
Water circuit / flow meter problems (water circuit blocked or no flow
meter signal)
Boiler temperature sensor short circuited
Boiler temperature sensor open circuit
The boiler temperature has exceeded the maximum allowed value
(165°c)
The boiler temperature has not increased by x°c in y sec (boiler power
supply disconnected, incorrect boiler fitted must be a 1300W boiler,
partial power supply to boiler, cut out thermostat tripped)
Mains voltage trouble
DESCRIPTION
Rev.01 February 2010
05 SERVICE MODE
Page 7 / 07