Dose Self-Learning - Saeco Syntia Service Manual

Hide thumbs Also See for Syntia:
Table of Contents

Advertisement

SYNTIA
4.8
Dose self-learning (SAS)
The aim of this function is to automatically regulate the average dose of ground coffee (SELF-
LEARNING); this occurs by means of an algorithm based on three pieces of information detected
by the machine electronic board:
1. Number of coffee grinder pulses during the grinding cycle
2. Max. average value of the power consumed by the group motor during the coffee brewing cycle
3. Aroma selected by the user
The algorithm compares the maximum average value of the power consumed by the group motor
with the value listed in the table for the selected aroma, in order to calculate the new grinding
pulse value for the next coffee produced.
If the power consumption value is less than the minimum current value, the
grinding pulses will be increased by 2.
If the power consumption value is greater than the maximum current value, the grinding pulses
will be decreased by 4.
If the power consumption value falls within the "over-torque" interval, the product will be
dispensed and the grinding pulses will be decreased by 10.
If the power consumption value falls within the "abort cycle" interval, the pad will be expelled and
the grinding pulses will be decreased by 10.
If the "pre-ground" flavour is selected by the user, no modification will be made.
This guarantees that, regardless of the coffee type used, the grinding level setting
and the wear on the grinders always remains constant.
Setting/Status
A
Mild aroma
B
Medium Aroma
C
Strong Aroma
D
Over-limit
E
Over-torque
F
Abort cycle
Important:
For perfect operation, machine adjustment should take place in the area of the fields
highlighted in green (A, B, C). When the type or brand of coffee is changed, there may be
variations in the size of the beans and their stickiness or roasting level. This leads to variations
in power consumption (mA), with resulting excessive or insufficient doses (until the necessary
adjustments have been made to compensate for this change).
Caution: In the case of excessive dosage, powder may be expelled into the dreg
drawer. This is not a fault, but can occur during preliminary operation or after a
service.
Saeco International Group
Power consumption
in mA
200 - 300 mA
301 - 450 mA
451 - 600 mA
601 - 800 mA
801 - 1,000 mA
> 1000 mA
Rev.01 February 2010
Pulses corrected in the next grinding process
Exceeded by
- 4
- 4
- 4
- 4
- 10
- 10
04 OPERATING LOGIC
Deficient by
+2
+2
+2
Page
06
/ 06

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents