7.6.

Boiler disassembly

1
7.7.

Valve disassembly

1
Saeco International Group
2
3
2
5
4
1) Remove the coffee grinder noise reduction
cover
2) Remove the boiler insulation
3) Unscrew the screws shown
4) Loosen the screw and remove the plastic
support.
Disconnect the hoses and the connections
1) Remove the boiler pin
2) Remove the control knob cover
and unscrew the screw as indicated
3) Lift and remove the dispenser
3
assembly, slide out the fork clip
shown and unscrew the screws
holding the front piece
4) Unscrew the screws shown to
remove the front piece support
5) Remove the spring washer and
the control knob gear (steam/water)